Specifications

38
BCN-B11127-479*
Class No. Symbol Name and Function Initial Value Unit Setting Range
40 OVA 0
41
For manufacturing setting
0
42 *ZPS Zeroing position data
Used to set the current position on completion of zeroing.
0 10
S
TM
m
32768
to
32767
43 DCT Moving distance after proximity dog
Used to set the moving distance after proximity dog in count type zeroing.
1000 10
S
TM
m
0 to 65535
44 ZTM Stopper type zeroing stopper time
In stopper type zeroing, used to set the time from when the machine part
is pressed against the stopper and the torque limit set in parameter
No.45(ZTT) is reached to when the home position is set.
100 ms 5 to 1000
45 ZTT Stopper type zeroing torque limit
Used to set the torque limit value relative to the max. torque in [%] in
stopper type zeroing.
15 % 1 to 100
46
47
LMP Software limit
Used to set the address increment side software stroke limit. The software
limit is made invalid if this value is the same as in "software limit
".
Set the same sign to parameters No.46 and 47. Setting of different signs will
result in a parameter error.
Set address:
Upper 3
digits
Lower 3
digits
Parameter No. 47
Parameter No. 46
0 10
ST
M
m
999999
to
999999
48
49
LMN Software limit
Used to set the address decrement side software stroke limit. The software
limit is made invalid if this value is the same as in "software limit
".
Set the same sign to parameters No.48 and 49. Setting of different signs will
result in a parameter error.
Set address: 
Upper 3
digits
Lower 3
digits
Parameter No. 49
Parameter No. 48
0 10
ST
M
m
999999
to
999999
50
51
LPP Position range output address
Used to set the address increment side position range output address. Set the
same sign to parameters No.50 and 51. Setting of different signs will result in
a parameter error.
Set address:
Upper 3
digits
Lower 3
digits
Parameter No. 51
Parameter No. 50
0 10
ST
M
m
999999
to
999999