Specifications

Table Of Contents
α
2 Simple Application Controllers
The Command String 7
7 - 30
Step 4
The
Hourly
value is a five digit binary value for 10. 10 (dec) = 01010 binary.
Step 5
The
Minute
value is a 6 digit value for 0. 0 (dec) = 000000 binary.
Step 6
Finally, the On/Off value is 1 for On and the table is complete.
To values to put into the Command String must be in Hexadeximal values. Combine the table
bits b4-b7 and b0-b3 to give a two digit Hexadecimal number.
Step 7
Level b7 b6 b5 b4 b3 b2 b1 b0
RTC+0 “1” “0” “0” “0” “0” “0” “0” “0”
RTC+1 Wk 5 = 0 Wk 4 = 0 Wk 3 = 0 Wk 2 = 0 Wk 1 = 1 Sat = 0 Fri = 1 Thur = 0
RTC+2 Wed = 1 Tues = 0 Mon = 1 Sun = 0 Hour = 0 Hour = 1 Hour = 0 Hour = 1
RTC+3 Hour = 0 Min Min Min Min Min Min On/Off
Level b7 b6 b5 b4 b3 b2 b1 b0
RTC+0 “1” “0” “0” “0” “0” “0” “0” “0”
RTC+1 Wk 5 = 0 Wk 4 = 0 Wk 3 = 0 Wk 2 = 0 Wk 1 = 1 Sat = 0 Fri = 1 Thur = 0
RTC+2 Wed = 1 Tues = 0 Mon = 1 Sun = 0 Hour = 0 Hour = 1 Hour = 0 Hour = 1
RTC+3 Hour = 0 Min = 0 Min = 0 Min = 0 Min = 0 Min = 0 Min = 0 On/Off
Level b7 b6 b5 b4 b3 b2 b1 b0
RTC+0 “1” “0” “0” “0” “0” “0” “0” “0”
RTC+1 Wk 5 = 0 Wk 4 = 0 Wk 3 = 0 Wk 2 = 0 Wk 1 = 1 Sat = 0 Fri = 1 Thur = 0
RTC+2 Wed = 1 Tues = 0 Mon = 1 Sun = 0 Hour = 0 Hour = 1 Hour = 0 Hour = 1
RTC+3 Hour = 0 Hour = 0 Min = 0 Min = 0 Min = 0 Min = 0 Min = 0 On =1
Table 7.16: Weekly Setting Table with Hexadecimal Values
Level b7 b6 b5 b4 b3 b2 b1 b0
Hexadecimal Command
String Value
RTC+010000000 80 H
RTC+100001010 0A H
RTC+210100101 A5 H
RTC+300000001 01 H