Instruction manual
2 - 91 
2 SYSTEM CONFIGURATION 
2.5.9 SSCNET  cables 
Between the Motion CPU module and servo amplifiers, or servo amplifier and servo 
amplifier connected by SSCNET
 cable. When using the Q172D(S)CPU, SSCNET  
cable for connection to servo amplifier can be used for only 1 line. (Connect to CN1.) 
When using the Q173D(S)CPU, SSCNET
 cables for connection to servo amplifier 
can be used for up to 2 lines. (Connect to CN1 and CN2.) 
Up to 16 servo amplifiers can be connected to SSCNET
(/H) per 1 line. 
(However, when using the Q172DCPU(-S1), up to 8 servo amplifiers can be 
connected.) 
(1) SSCNET  cable specifications 
Model name  Cable length [m(ft.)] Description 
MR-J3BUS M 
(Standard cord for 
inside panel) 
MR-J3BUS015M 0.15 (0.49) 
• Motion CPU 
Servo amplifier 
• Servo amplifier 
Servo amplifier 
MR-J3BUS03M 0.3 (0.98) 
MR-J3BUS05M 0.5 (1.64) 
MR-J3BUS1M 1 (3.28) 
MR-J3BUS3M 3 (9.84) 
MR-J3BUS M-A 
(Standard cable for 
outside panel) 
MR-J3BUS5M-A 5 (16.40) 
MR-J3BUS10M-A 10 (32.81) 
MR-J3BUS20M-A 20 (65.62) 
MR-J3BUS M-B 
(Long distance cable) 
MR-J3BUS30M-B 30 (98.43) 
MR-J3BUS40M-B 40 (131.23) 
MR-J3BUS50M-B 50 (164.04) 