Service manual

5
SPECIFICATION
3
Model MS-A09WA MS-A12WA
Indoor unit model MS-A09WA MS-A12WA
External nish White
Power supply V, phase, Hz 115, 1, 60
Max.-fuse size (time delay) /
Disconnect switch
A15
Min. circuit ampacity A 1.2
Fan motor F.L.A 0.95
Air ow
Low–Med.–High–Powerful
COOL
Dry (Wet)
CFM
183 - 261 - 335 - 367
(162 - 233 - 300 - 328)
222 - 286 - 406 - 446
(198 - 254 - 363 - 399)
Moisture removal pt./h 2.7 3.2
Sound level
Low–Med.–High–Powerful
dB(A) 26 - 32 - 40 - 42 33 - 38 - 45 - 47
Cond. drain connection O.D. in. 5/8
Dimensions
W
in.
30-11/16
D 8-1/4
H 11/-3/4
Weight Ib. 23
Remote controller Wireless type
Control voltage (by built-in transformer) 115 VAC
NOTE : Test conditions are based on ARI 210/240
1 : Rating conditions (cooling) — Indoor : 80˚FDB, 67˚FWB, Outdoor : 95˚FDB, (75˚FWB) Rated frequency : 60Hz
Operating Range
Indoor intake air temperature Outdoor intake air temperature
Cooling
Maximum 95˚FDB, 71˚FWB 115˚FDB
Minimum 67˚FDB, 57˚FWB 67˚FDB