Service manual

14
Main functions of LED (when both No. 1 and 2 of
SW3
are ¨OFF¨)
NOTES :If the operation stops to function of the protection device, the check display flashes.
How to use SW1 and 2
Pressing
SW1
erases the past check contents loaded on the micro-
computer.
The output display (light) remains during operation but pressing
SW2
displays the past check contents in flashing mode. Pressing the
switch again returns to output display (light).
The connector marked
s
ı
— is to turn the compressor ON-OFF during servicing.
The compressor stops by disconnecting the white connector as shown at the right.
Since LD8 lights when normal power is turned "ON", check the power supply with
the "ON" or "OFF" LD8.
Since the indoor transformer (T) is connected with 230V power, if 208V power is
used, change the wiring connection in the following Procedure.
Since the indoor and outdoor connecting wires has polarity, make sure to connect the same terminal numbers (1, 2) for indoor and outdoor units.
CAUTION FOR INDOOR AND OUTDOOR CONNECTING WIRES
CAUTION FOR POWER SUPPLY WIRING
CAUTION FOR SERVICING
FROM INDOOR UNIT
CONNECTING WIRES
12V DC (polar)
POWER SUPPLY
208/230V
1phase 60Hz
1
2
TB3
L1
L2
GR
TB1
O.B
LED
TH3
YLW
BRN 11.5V AC
RED
RED
WHT
WHT
WHT
RED
R
R
S
C
T
C
U
52C
MC
51C
W
GRN
WHT
BLU
BLU
WHT
12
RED
WHT
RED
ORN
GRY
GRY
WHT
WHT
BLU
YLM
YLM
YLM
YLM
RED
RED
BLU
BLU
WHT
BLU
RED
ORN
15.5V AC
208V
230V
T
ORN
SW1
SW2
SW3
CN3
CN2
TRF 52C
52C
CH
ZNR
FC
C3
MF3
26C
51CM
63H2
63H2
MF3
R/1
F3
S/2 T/3
CH
X12
X12 X11
X11
CN6T
OFF
ON
2
2
1
1
1
S
A
B
5
234
4
LD8
LD7
LD6
LD5
LD4
LD3
LD2
LD1
56
ORN 36.0V AC
MODELS : PU18EK
SYMBOL
C
NAME
COMPRESSOR CAPACITOR
C3 FAN CAPACITOR
CH CRANKCASE HEATER
CN3<O. B>
CONNECTING WIRES INDOOR/OUTDOOR
CONNECTOR
CN6T<O. B> TRANSFORMER CONNECTOR
SYMBOL
LD1 ~ LD8
NAME
LED <CHECK, SERVICE>
MC COMPRESSOR
MF3
OUTDOOR FAN MOTOR (INNER THERMOSTAT)
O. B OUTDOOR CONTROLLER BOARD
SW1, 2, 3<O. B>
SELECT SWITCH <CHECK, SERVICE>
T TRANSFORMER
FC <O. B> FAN CONTROLLER
F3 <O. B> FUSE <6A>
SYMBOL
TH3
NAME
OUTDOOR COIL THERMISTOR
X11 <O. B> CRANKCASE HEATER RELAY
X12 <O. B> COMPRESSOR RELAY
ZNR <O. B> VARISTOR
52C CONTACTOR
63H2 HIGH PRESSURE SWITCH <PROTECT>
TB1 POWER SUPPLY TERMINAL BLOCK
TB3
CONNECTING WIRES INDOOR/OUTDOOR
TERMINAL BLOCK
51C OVERCURRENT RELAY
LED NO. Output display (light) Check display (flush)
LD1 Compressor indoor command
LD2
LD3
Pipe temperature sensor
short / open
LD4 Compressor ON 63H2 functions
LD5 Outdoor fan ON
LD6
LD7 TH3 overheat protection
LD8 Crankcase heater ON Defective input
White connector
When power Supply is 208V
RED WHITE208V
ORANGE 230V
OC247-E--1.qxp 04.8.11 4:25 PM Page 14