5-4. STANDARD OPERATION DATA
Heat pump type (1)
The unit of pressure has been changed to Mpa on tha international system of unit (Sl system).
The converted score against tha traditional unit system can be gotten according to the formula below.
1(Mpa) = 10.2(kgf/
ff
)
Service Ref.
Mode
Capacity
Input
Indoor unit Service Ref.
Phase , Hz
Volts
Amperes
Outdoor unit Service Ref.
Phase , Hz
Volts
Amperes
Discharge pressure
Suction pressure
Discahrge temperature
Condensing temperature
Suction temperature
Ref.pipe length
Intake air
temperature
Discharge air
temperature
Intake air
temperature
BF
SHF
W
kW
˚C
˚C
˚C
˚C
˚C
D.B.
D.B.
W.B.
D.B.
W.B.
˚C
˚C
˚C
m
MPa
MPa
Outdoor
side
Indoor side Refrigerant circuit Electrical circuit Total
Cooling Heating Cooling Heating
PKA-RP1.6GAL PKA-RP2GAL
PKA-RP1.6GAL
1 , 50
230
PUHZ-RP1.6VHA
1 , 50
230
PKA-RP2GAL
1 , 50
230
PUHZ-RP2VHA
1 , 50
230
3,600
1.03
0.33
4.29
70
46
15
5
27
19
14.8
35
24
0.84
0.11
4,100
1.27
0.33
5.36
81
48
2
5
20
15
38.3
7
6
4,600
1.63
0.33
6.98
76
49
3
5
27
19
13.3
35
24
0.74
0.13
4,500
1.40
0.33
5.95
82
53
2
5
20
15
40.2
7
6
2.68
1.01
3.05
0.73
2.89
0.79
3.18
0.72