Specifications

MS/MSY
Model Speciļ¬cations
(air conditioners)
* Use ICM-326HM-1 Head Pressure Controller Accessory for Non-INVERTER
Models (for low outdoor ambient cooling only).
*Non-INVERTER Models
Indoor
Model #
*MS-A09WA *MS-A12WA MSY-GE09NA-8 MSY-GE12NA-8
MSY-GE15NA-8 MSY-GE18NA-8 MSY-GE24NA MSY-D30NA-8 MSY-D36NA-8
Outdoor
Model #
*MU-A09WA *MU-A12WA MUY-GE09NA MUY-GE12NA
MUY-GE15NA-1 MUY-GE18NA-1 MUY-GE24NA MUY-D30NA-1 MUY-D36NA-1
Rated Cooling
Capacity
(Btu/h)
9,500 12,000 9,000 12,000 14,000 17,200 22,500 30,700 34,600
Cooling
Capacity
Range (Btu/h)
9,500 12,000 3,800-12,200 3,800-13,600 3,100-18,200 3,700-18,700 8,200-31,400 9,800-30,700 9,800-34,600
SEER 13 13 21 20.5 21 19.2 19 16 15.1
Lineset Size
(Liquid x Gas)
1/4" x 3/8" 1/4" x 1/2" 1/4" x 3/8" 1/4" x 3/8"
1/4" x 1/2" 1/4" x 1/2" 3/8" x 5/8" 3/8" x 5/8" 3/8" x 5/8"
Lineset
Length/
Height Max.
Separation
65'/35' 65'/35' 65'/40' 65'/40'
65'/40' 100'/50' 100'/50' 100'/50' 100'/50'
Breaker Size 15 AMP 20 AMP 15 AMP 15 AMP 15 AMP 15 AMP 20 AMP 25 AMP 25 AMP