Specifications

Test Run
1. Turn power on to outdoor unit.
2. Press the emergency operation
button once. The test will run for 30
minutes. If the LED light blinks every
0.5 seconds, verify the indoor/outdoor connecting wire
is installed properly. After the test run, the emergency
COOL mode (75°F) will operate.
3. To stop operation, press the emergency operation
button several times until all LED lights turn off. See
operation manual for details.
Checking the Remote (Infrared) Signal Reception
1. Press the ON/OFF button on the remote controller and
listen for a beep from the indoor unit.
2. Press the ON/OFF button again to turn the air
conditioner off.
3. After the compressor stops in the outdoor unit, the
restart prevention device will activate. This causes the
compressor to stop operation for three minutes, which
protects the air conditioner.
Caution:
After finishing the test run or checking the remote (infrared)
signal reception, use emergency operation button or remote
controller to turn unit off before turning power supply off.
If this sequence is not followed properly, the unit will start
operating automatically when the power supply resumes.