Service manual

5
SPECIFICATION
3
Specifications and rating conditions of main electric parts
NOTE : Test conditions are based on ISO 5151
Cooling : Indoor Dry-bulb temperature 27 : Wet-bulb temperature 19 :
Outdoor Dry-bulb temperature 35 :
Heating : Indoor Dry-bulb temperature 20 :
Outdoor Dry-bulb temperature 7 : Wet-bulb temperature 6 :
Refrigerant piping length (one way): 5 m
1 Measured under rated operating frequency.
MSZ-FD25VA MSZ-FD35VA
Single phase
230 V, 50 Hz
RC0J40-GF
798O295O257
12
4
672
516/378/276
1,190
950/740/580
4
KM08A
Indoor model
Power supply
Power input 1
Running current 1
Fan motor current 1
Fan motor model
Dimensions WOHOD
Weight
Color
Air direction
Air flow
(Super High)
Air flow
(High/Med./Low)
Sound level
(Super High)
Sound level
(High/Med./Low)
Fan speed
(Super High)
Fan speed
(High/Med./Low)
Fan speed regulator
Remote controller model
W
A
A
mm
kg
K /h
K /h
dB(A)
dB(A)
rpm
rpm
Electrical
data
Special remarks
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
MSZ-FD25VAS MSZ-FD35VAS
26
31
0.25
0.30
0.25
0.30
726
552/402/270
42
43
36/29/20
1,270
1,010/780/570
28
33
0.27
0.32
0.27
0.32
750
552/402/282
43
44
36/29/21
1,300
1,010/780/590
PURE WHITE SILVER PURE WHITE SILVER
250 V 3.15 A
MP20Z 12 VDC 300 " (at 25 ˚C)
MSFBC20C29 12 VDC 350 " (at 25 ˚C)
MSBPC20M11 12 VDC 300 " (at 25 ˚C)
S10K320E3K1
A2TPMI 23A FOV50 OBA060 P8L1 J4S
3P
Fuse
i-see Sensor motor
Horizontal vane motor
Vertical vane motor
Varistor
i-see Sensor
Terminal block
(F11)
(MT)
(MV1)
(MV2)
(NR11)
(RR)
(TB)
OBH488A-1.qxp 07.9.25 11:33 AM Page 5