Product Sheet

Convenience
Ampere Limit Adjustment
Dipswitch settings can be used to adjust the maximum electrical
current for operation. This function is highly recommended for
managing energy costs.
*Maximum capacity is lowered with the use of this function.
Auto Changeover
The air conditioner automatically switches between heating and
cooling modes to maintain the desired temperature.
Auto Restart
Especially useful at the time of power outages, the unit turns back
on automatically when power is restored.
Auto Fan Speed Mode
The airflow speed mode adjusts the fan speed of the indoor unit
automatically according to the present room conditions.
“i-Save” Mode
“i-Save” is a simplified setting function that recalls the preferred
(preset) temperature by pressing a single button on the remote
controller. Press the same button twice in repetition to immediately
return to the previous temperature setting. Using this function
contributes to comfortable waste-free operation, realising the most
suitable air conditioning settings and saving on power consumption
when, for example, leaving the room or going to bed.
Low-Temperature Cooling
Intelligent fan speed control in the outdoor unit ensures optimum
performance even when the outside temperature is low.
On/Off Operation Timer
Use the remote controller to set the times for the air conditioner to
turn On/Off.
Operation Lock
To accommodate specific-use applications, cooling or heating
operation can be specified when setting the control board of the
outdoor unit. A convenient option when a system needs to be
configured for exclusive cooling or heating service.
System Control
COMPO (Simultaneous Multi-Unit Operation)
Multiple indoor units can be connected to a single outdoor unit.
(Depending on the unit combination, connection of up to four units is
possible; however, all indoor units must operate at the same settings.)
M-Net Connection
Units can be connected to MELANS system controllers (M-NET
controllers) such as the AE-200E.
MXZ Connection
Connection to the MXZ multi-split outdoor unit is possible.
PAR-33MAA Control
Units are compatible for use with the PAR-33MAA remote controller,
which has a variety of management functions including a weekly timer.
System Group Control
The same remote controller is capable of controlling the operational
status of up to 16 refrigerant systems.
Wi-Fi Interface
Interface enabling users to control air conditioners and check operating
status via devices such as personal computers, tablets and smartphones.
Optional upgrade adapter required per unit.
Installation & Maintenance
Cleaning-Free Pipe Reuse*
The application of pipe reuse technology such as Mitsubishi Electric’s
original hard alkyl benzene oil makes it possible to reuse the same
piping, thereby allowing cleaning-free renewal of air conditioning
systems that use R22 refrigerant.
*Cleaning-Free Pipe Reuse Technology specifically applies to piping which
is contaminated with chlorine residue, iron particles and slime. These
contaminants are typically found in which the previous system utilised R22
refrigerant. Cleaning-Free Pipe Reuse Technology cannot be used to clean
pipes which contain foreign matter other than what can be generated from an
operating air conditioner.
Error Log Function
Operation errors are recorded, allowing confirmation when needed.
Flare Connection
Flare connection to cooling pipe work is possible.
Quick Clean
The cover panel can be quickly removed for washing and the airflow
vents can be opened without any special tools, making it easy to
clean the inside of the air conditioner in minutes. Periodic cleaning of
the air conditioner is recommended to maintain optimum operating
efficiency and energy savings.
Self-Diagnostic Function (Check Code Display)
Check codes are displayed on the remote controller or the operation
indicator to inform the user of malfunctions detected.
21