Notes:
Indoor Unit
MCA ...................................................................................... 1.0 A
Blower Motor (ECM) .....................................................0.67 F.L.A.
Blower Motor Output .............................................................30 W
Airow (Lo - Med - Hi - Super Hi - Powerful)
Cooling ........................................ 137-167-221-304-381 Dry CFM
117-143-190-261-328 Wet CFM
Heating ........................................140-167-225-325-437 Dry CFM
Sound Pressure Level (Lo - Med - Hi - Super Hi - Powerful)
Cooling ....................................................... 20-23-29-36-40 dB(A)
Heating ....................................................... 20-24-29-36-42 dB(A)
External Finish Color ......................................... Munsell 1.0Y 9.2/0.2
External Dimensions
Inches: ................................12 + 11/16 H x 36-7/16 W x 9-3/16 D
mm: ..................................................305 +17 H x 925 W x 234 D
Weight Unit ...................................................................29 lbs. / 12 kg
Field Drainpipe Size O.D. ........................................ 19/32 In. / 15mm
Outdoor Unit
MCA ....................................................................................... 11 A
Fan Motor (ECM) .........................................................0.50 F.L.A.
Sound Pressure Level
Cooling *1........................................................................48 dB(A)
Heating *2 .......................................................................49 dB(A)
External Finish Color ............................................ Munsell 3Y 7.8/1.1
Dimensions
Inches:..........................................21-5/8 H x 31-1/2 W x 11-1/4 D
mm: ..........................................................550 H x 800 W x 285 D
Weight ..........................................................................81 lbs. / 36 kg
Refrigerant Type ...................................................................... R410A
Refrigerant Pipe
Gas Side O.D. ...................................................... 3/8“ x 9.52 mm
Liquid Side O.D. .................................................... 1/4” x 6.35 mm
Max. Refrigerant Pipe Length
Height Difference ........................................................... 40’ / 12m
Length ........................................................................... 65’ / 20m
Connection Method
Indoor/Outdoor .................................................................... Flared
Cooling*1
Rated Capacity..........................................................9,000 Btu/h
Capacity Range...........................................1,700 - 12,000 Btu/h
Rated Total Input ..............................................................560 W
Maximum Total Input ......................................................1,000 W
SEER ..................................................................... 30.5 Btu/h/W
Heating at 47° F*2
Rated Capacity........................................................10,900 Btu/h
Capacity Range...........................................1,600 - 18,000 Btu/h
Rated Total Input ..............................................................710 W
Maximum Total Input .....................................................1,470 W
HSPF ...................................................................... 13.5 Btu/h/W
Heating at 17° F *3
Rated Capacity..........................................................6,700 Btu/h
Max. Capacity .........................................................12,200 Btu/h
Rated Total Input ..............................................................600 W
Maximum Total Input .....................................................1,440 W
Heating at 5° F *4
Max. Capacity .........................................................10,900 Btu/h
Maximum Total Input .....................................................1,500 W
Rating Conditons:
*1 Cooling | Indoor: 80º F (27º C) DB / 67º F (19º C) WB
*1 Cooling | Outdoor: 95º F (35º C) DB / 75º F (24º C) WB
*2 Heating at 47ºF | Indoor: 70º F (21º C) DB / 60º F (16º C) WB
*2 Heating at 47ºF | Outdoor: 47º F (8º C) DB / 43º F (6º C) WB
*3 Heating at 17º F | Indoor: 70º F (21º C) DB / 60º F (16º C) WB
*3 Heating at 17º F | Outdoor: 17º F (-8º C) DB / 15º F (-9º C) WB
*4 Heating at 5º F | Indoor: 70º F (21º C) DB / 60º F (16º C) WB
*4 Heating at 5º F | Outdoor: 5º F (-15º C) DB / 5º F (-15º C) WB
Electrical Requirements
Power Supply ....................................... 208 / 230V, 1-Phase, 60 Hz
Breaker Size .............................................................................. 15 A
Voltage
Indoor - Outdoor S1-S2 ......................AC 208 / 230V
Indoor - Outdoor S2-S3 .........................DC +/- 24V
Indoor - Remote Controller.....................MKH1 DC 3V
PAR-31MAA DC 12V
PAC-YT53CRAU DC 12V
Operating Conditons
Cooling
Indoor Intake Air Temp...(Max.) 90º F (32º C) DB / 73º F (23º C) WB
(Min.) 67º F (19º C) DB / 57º F (14º C) WB
Outdoor Intake Air Temp. ................(Max.) 115º F (46º C) DB
(Min.) 14º F (-10º C) DB
Heating
Indoor Intake Air Temp. ..(Max.) 80º F (27º C) DB / 67º F (19º C) WB
(Min.) 70º F (21º C) DB / 60º F (16º C) WB
Outdoor Intake Air Temp. (Max.)75º F (24º C) DB / 65º F (18º C) WB
(Min.) -13º F (-25º C) DB / -15º F (-26º C) WB**
** System cuts out at -18º F (-28º C) to avoid thermistor error, but recovers from
cutout operation and automatically restarts at -13º F (-25ºC).
SPECIFICATIONS: MSZ-FH09NA & MUZ-FH09NA