MFZ-KJ Operation Manual

En-12
Installation place
Avoid installing the air conditioner in the following places.
Where there is much machine oil.
Salty places such as the seaside.
Where sulfi de gas is generated such as hot spring, sewage, waste water.
Where oil is splashed or where the area is lled with oily smoke (such as cook-
ing areas and factories, in which the properties of plastic could be changed
and damaged).
Where there is high-frequency or wireless equipment.
Where the air from the outdoor unit air outlet is blocked.
Where the operation sound or air from the outdoor unit bothers the house next door.
Electrical work
Provide an exclusive circuit for the power supply of the air conditioner.
Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
INSTALLATION PLACE AND
ELECTRICAL WORK
SPECIFICATIONS
1
Set to the highest temperature in manual COOL mode,
and operate for 3 to 4 hours. Page 5
This dries the inside of the unit.
Moisture in the air conditioner contributes to favorable conditions for
growth of fungi, such as mold.
2
Press
to stop the operation.
3
Turn off the breaker and/or disconnect the power sup-
ply plug.
4
Remove all batteries from the remote controller.
When using the air conditioner again:
1
Clean the air fi lter. Page 10
2
Check that the air inlet and outlet of the indoor and
outdoor units are not blocked.
3
Check that the ground is connected correctly.
4
Refer to the “PREPARATION BEFORE OPERATION”,
and follow the instructions. Page 4
WHEN THE AIR CONDITIONER IS NOT
GOING TO BE USED FOR A LONG TIME
DB: Dry Bulb
WB: Wet Bulb
Indoor Outdoor
Cooling
Upper limit
90°F (32.2°C) DB
73°F (22.8°C) WB
115°F (46.1°C) DB
Lower limit
67°F (19.4°C) DB
57°F (13.9°C) WB
14°F (-10°C) DB
Heating
Upper limit
80°F (26.7°C) DB
75°F (23.9°C) DB
65°F (18.3°C) WB
Lower limit
70°F (21.1°C) DB
-13°F (-25°C) DB
-14°F (-25.6°C) WB
Guaranteed operating range
Note:
1. The guaranteed operating range value is for 1:1 System Application.
2. If the outdoor temperature is below the lower limit of guaranteed operating range, the outdoor unit may
stop operation until the outdoor temperature exceeds the lower limit.
wall, etc.
For the optimum effi ciency
and to extend the life time of
using, the outdoor unit should
be installed in a well-ventilated
dry place.
10 ft. (3 m) or
more
The installation location of the outdoor unit should be
at least 10 ft. (3 m) away from the antennas for TV
sets, radios, etc. In areas where the reception is weak,
provide greater space between the outdoor unit and
the antenna of the affected device if operation of the air
conditioner interferes with radio or TV reception.
(KJ09, 12/
KJ15, 18)
To prevent the effects
of a fl uorescent lamp,
keep as far apart as
possible.
Inverter-type
uorescent lamp
Keep a space
to prevent the
picture distortion
or the noise.
Radio
TV
Cordless phone
or portable
phone
3 ft. (1 m)
or more
3 ft. (1 m)
or more
4 in.
(100 mm)
or more
8/20 in.
(200/500 mm)
or more
JG79Y070H01_en.indd 12 2015/11/18 9:23:08