M-Series SEZ-KA Engineering Manual

SEZ Ducted Heat Pump Systems (August 2014)
SEZ-1
© 2014 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specication may be subject to change without notice.
M-SERIES SINGLE ZONE SYSTEMS
SEZ DUCTED HEAT PUMP SYSTEMS
1. INDOOR UNITS .........................................................................................................................................................SEZ-3
2. OUTDOOR UNITS .....................................................................................................................................................SEZ-4
3. SYSTEM .....................................................................................................................................................................SEZ-5
3-1. SPECIFICATIONS ..................................................................................................................................................SEZ-6
SEZ-KD09NA4 SEZ-KD12NA4 ...............................................................................................................................SEZ-6
SEZ-KD15NA4 SEZ-KD18NA4 ...............................................................................................................................SEZ-7
SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA .........................................................................................................SEZ-8
SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA .........................................................................................................SEZ-9
SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA .......................................................................................................SEZ-10
Efciency Ratings ................................................................................................................................................... SEZ-11
3-2. EXTERNAL DIMENSIONS....................................................................................................................................SEZ-12
SEZ-KD09NA4 .......................................................................................................................................................SEZ-12
SEZ-KD12NA4 .......................................................................................................................................................SEZ-12
SEZ-KD15NA4 .......................................................................................................................................................SEZ-12
SEZ-KD18NA4 .......................................................................................................................................................SEZ-12
SUZ-KA09NA.TH SUZ-KA12NA.TH SUZ-KA15NA.TH ...................................................................................SEZ-13
SUZ-KA18NA.TH ...................................................................................................................................................SEZ-14
3-3. CENTER OF GRAVITY .........................................................................................................................................SEZ-15
3-4. ELECTRICAL WIRING DIAGRAMS......................................................................................................................SEZ-16
SEZ-KD09NA4.TH SEZ-KD12NA4.TH SEZ-KD15NA4.TH SEZ-KD18NA4.TH ...........................................SEZ-16
SUZ-KA09NA.TH SUZ-KA12NA.TH ...................................................................................................................SEZ-17
SUZ-KA15NA.TH ...................................................................................................................................................SEZ-18
SUZ-KA18NA.TH ...................................................................................................................................................SEZ-19
3-5. REFRIGERANT SYSTEM DIAGRAMS ................................................................................................................SEZ-20
SEZ-KD09NA4.TH SEZ-KD12NA4.TH SEZ-KD15NA4.TH SEZ.KD18NA4.TH............................................SEZ-20
SUZ-KA12NA.TH SUZ-KA15NA.TH ...................................................................................................................SEZ-21
3-6. CAPACITY CORRECTION CURVE BY TEMPERATURE ....................................................................................SEZ-22
(1) Cooling Performance Curve..............................................................................................................................SEZ-22
(2) Heating Performance Curve .............................................................................................................................SEZ-23
3-7. CAPACITY CORRECTION TABLE BY TEMPERATURE ......................................................................................SEZ-25
(1) Cooling Capacity ............................................................................................................................................... SEZ-25
(2) Heating Capacity ..............................................................................................................................................SEZ-26
(3) M-Series Cooling Correction ............................................................................................................................. SEZ-27
(4) M-Series Defrost Correction .............................................................................................................................SEZ-27
(5) M-Series Heating Correction.............................................................................................................................SEZ-28

Summary of content (46 pages)