M-Series SEZ-KA Engineering Manual

SEZ Ducted Heat Pump Systems (August 2014)
SEZ-9
© 2014 Mitsubishi Electric US, Inc.
Due to continuing improvement, above specication may be subject to change without notice.
SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA
Model name
Indoor unit SEZ-KD09NA4.TH SEZ-KD12NA4.TH SEZ-KD15NA4.TH SEZ-KD18NA4.TH
Outdoor unit
SUZ-KA09NA.TH SUZ-KA12NA.TH SUZ-KA15NA.TH SUZ-KA18NA.TH
Indoor unit
MCA A 1
MOCP A 15
Blower Motor F.L.A 0.51 0.57 0.74
Blower Motor Output W 96
Air ow DRY
(Lo-Mid-Hi) WET
CMM 5.5 - 7 - 9 7 - 9 - 11 10 - 12.5 - 15 12 - 15 - 18
CMM 4.9 - 6 - 8 6 - 8 - 10 9 - 11.2 - 14 11 - 14 - 17
Air ow DRY
(Lo-Mid-Hi) WET
CFM 194 - 247 - 317 247 - 317 - 388 353 - 441 - 529 423 - 529 - 635
CFM 174 - 222 - 285 222 - 285 - 349 317 - 396 - 476 381 - 476 - 572
External pressure in.WG [Pa] 0.02 / 0.06 / 0.14 / 0.20 [5/15/35/50]
Sound level (Lo-Mi-Hi)
dB (A)
23 - 26 - 30 23 - 28 - 33 30 - 34 - 37 30 - 34 - 38
Dimension
Unit
W:mm [inch] 790 [31-1/8] 990 [39] 1190 [46-7/8]
D:mm [inch] 700 [27-9/16]
H:mm [inch] 200 [7-7/8]
Weight
Unit
kg 19 22 24 28
lbs 42 50 54 62
Field Drain pipe O.D.
mm [inch] 32 [1-1/4]
Remote Controller
Optional parts
NOTES : *1.Rating conditions (cooling)-Indoor : D.B. 26.7°C(80°F), W.B. 19.4°C(67°F) Outdoor : D.B. 35°C(95°F), W.B. 23.9°C(75°F)
(heating)-Indoor : D.B. 21.1°C(70°F), W.B. 15.6°C(60°F) Outdoor : D.B. 8.3°C(47°F), W.B. 6.1°C(43°F)
*2.Rating conditions(heating)-Indoor : D.B. 21.1°C(70°F), W.B. 15.6°C(60°F) Outdoor : D.B. -8.3°C(17°F), W.B. -9.4°C(15°F)
Operating range
Indoor intake air temperature
D.B. 35°C(95°F), W.B. 21.7°C(71°F)
D.B. 19.4°C(67°F), W.B. 13.9°C(57°F)
D.B. 26.7°C(80°F), W.B. 19.4°C(67°F)
D.B. 21.1°C(70°F), W.B. 15.6°C(60°F)
Outdoor intake air temperature
D.B. 46°C(115°F)
D.B. -10°C(14°F)
D.B. 24°C(75°F), W.B. 18°C(65°F)
D.B. -20°C(-4°F), W.B. -21°C(-5°F)
Cooling
Heating
Maximum
Minimum
Maximum
Minimum
3-1. SPECIFICATIONS