MXZ-SM42NAMHZ Service Manual

164
OCH789
OPERATING PROCEDURE PHOTOS/FIGURES
13. Removing the compressor (MC)
(1) Remove the service panel. (See Photo 1)
(2) Remove the top panel. (See Photo 1)
(3) Remove the cover panel (front). (Refer to procedure 8(5))
(4) Remove the cover panel (rear) (Refer to procedure 8(6))
(5) Remove the side panel (R). (Refer to procedure 8 (7))
(6) Remove 2 front cover panel fixing screws (5 × 12) and
remove the cover panel (front). (See Photo 4)
(7) Remove the electrical parts box. (See Photo 5)
(8) Remove the valve bed. (Refer to procedure 8 (4))
(9) Remove 3 separator fixing screws (4 × 10) and remove
the separator. (See Figure 2)
(10) Recover refrigerant.
(11) Remove the 3 compressor fixing nuts for motor using
spanner or adjustable wrench.
(12) Remove the welded pipe of compressor inlet and outlet
and then remove the compressor.
Note: Recover refrigerant without spreading it in the air.
Photo 13
Figure 2
14. Removing the accumulator
(1) Remove the service panel. (See Photo 1)
(2) Remove the top panel. (See Photo 1)
(3) Remove the cover panel (front). (Refer to procedure 13 (3))
(4) Remove the cover panel (rear). (Refer to procedure 13 (5))
(5) Remove the side panel (R). (Refer to procedure 8 (7))
(6) Remove the electrical parts box. (See Photo 5)
(7) Remove the valve bed. (See procedure 8 (4))
(8) Recover refrigerant.
(9) Remove 4 welded pipes of accumulator inlet and outlet.
(10) Remove 2 accumulator leg fixing screws (4 × 10). (See
Photo 15)
Note: Recover refrigerant without spreading it in the air.
Photo 14
Photo 15
Accumulator
Inlet
Outlet
Compressor
(MC)
Valve bed
Valve bed
xing screw
Valve bed
xing screws
Compressor
xing nuts
Separator
Accumulator
Separator
xing
screws
Separator
xing screw
Accumulator
Accumulator
leg
Accumulator
leg xing
screws