5. Operation
5.1. Description of “AUTO RESTART FUNCTION”
This unit is equipped with the auto restart function. When the main power is
turned on, the air conditioner will start operation automatically in the same
mode as set with the remote controller before the shutoff of main power.
If the unit was set to off with the remote controller before the shutoff of
main power, it will remain stopped even after the main power is turned on.
If the unit was in the TEST RUN before the shutoff of main power, it will
start operation, at main power on, in the same mode as set with the
remote controller before the TEST RUN.
Mode
Temperature setting
Fan speed
Remote Controller settings
Last operation mode
Last set temperature
Last set fan speed
5.2. Turning ON/OFF
<To Start Operation>
Press the ON/OFF button 1.
The ON lamp 1 and the display area come on.
Note:
When the unit is restarted, initial settings are as follows.
<To Stop Operation>
Press the ON/OFF button 1 again.
The ON lamp 1 and the display area go dark.
Note:
Even if you press the ON/OFF button immediately after shutting down the op-
eration is progress, the air conditioner will not start for about three minutes.
This is to prevent the internal components from being damaged.
5.3. Mode select
If the unit is off, press the ON/OFF button to turn it on.
1 The ON indicator should light up.
Press the operation mode ( ) button 2 and select the opera-
tion mode 2.
Cooling mode
Drying mode
Fan mode
Heating mode
Automatic (cooling/heating) mode
Ventillation mode
Only indicated on the following condition
Wired remote controller used
LOSSNAY connected
Information for multi system air conditioner (Outdoor
unit: MXZ series)
ss
ss
sMulti system air conditioner (Outdoor unit: MXZ series) can con-
nect two or more indoor units to one outdoor unit. According to the
capacity, two or more units can operate simultaneously.
When you try to operate two or more indoor units with one outdoor unit
simultaneously, one for the cooling and the other for heating, the opera-
tion mode of the indoor unit that operates earlier is selected. The other
indoor units that will start the operation later cannot operate, and will
flash the operation state.
In this case, set all the indoor units to the same operation mode.
There might be a case that the indoor unit, which is operating in
(AUTO) mode. It cannot change over to the operating mode (COOL
HEAT) and goes to stand by mode.
When indoor unit starts the operation while the outdoor unit is in defrost
mode, it takes a few minutes (max. about 15 minutes) to blow out the
warm air.
In heating operation, though an indoor unit that is not operating may it
get warm or the sound of refrigerant flowing may be heard, it is not mal-
functioning. That the refrigerant continuously flows into it.
Automatic operation
According to a set temperature, cooling operation starts if the room tem-
perature is too hot and heating operation starts if the room temperature
is too cold.
During automatic operation, if the room temperature changes and re-
mains 4 °F [2 °C] or more above the set temperature for 15 minutes, the
air conditioner switches to cooling mode. If the room temperature re-
mains 4 °F [2 °C] or more below the set temperature for 15 minutes, the
air conditioner switches to heating mode.
Because the room temperature is automatically adjusted in order to
maintain a fixed effective temperature, cooling operation is performed a
few degrees warmer and heating operation is performed a few degrees
cooler than the set room temperature once the temperature is reached
(automatic energy-saving operation).
Cooling mode
15 minutes (switches
from heating to cooling)
Set temperature +4 °F [2 °C]
Set temperature
Set temperature -4 °F [2 °C]
15 minutes (switches
from cooling to heating )
5.4. Temperature setting
ss
ss
sTo decrease the room temperature:
Press button 3 to set the desired temperature.
The selected temperature is displayed 3.
Each time you press the button, the temperature value decreases by 2 °F
[1 °C].
ss
ss
sTo increase the room temperature:
Press button 3 to set the desired temperature.
The selected temperature is displayed 3.
Each time you press the button, the temperature value decreases by 2 °F
[1 °C].
Available temperature ranges are as follows:
Cooling/Drying: 67 °F [19 °C] - 86 °F [30 °C]
Heating: 63 °F [17 °C] - 83 °F [28 °C]
Automatic: 67 °F [19 °C] - 83 °F [28 °C]
The display flashes either 47 °F [8 °C] - 103 °F [39 °C] to inform you if
the room temperature is lower or higher than the displayed temperature.
5.5. Fan speed setting
Press 5 button to select a desired fan speed.
Each time you press the button, available options change with the
display 5 on the remote controller, as shown below.
Fan speed
Remote controller display
Low Medium High Auto
3-stage
( )
( )
( )
s
Note:
Auto Mode is not recommended if this indoor unit is connected to a MXZ type
outdoor unit.
KB79K741H01_en.pm6 08.10.7, 9:33 AM5