OPERATING PROCEDURE PHOTOS/FIGURES
14. Removing the accumulator
(1) Remove the service panel. (See Photo 1)
(2) Remove the top panel. (See Photo 1)
(3) Remove the electrical parts box. (See Photo 5)
(4) Remove the valve bed. (See procedure 8 (4))
(5) Remove the cover panel (front). (Refer to procedure 8(5))
(6) Remove the cover panel (rear) (Refer to procedure 8(6))
(7) Remove the side panel (R). (Refer to procedure 8 (7))
(8) Recover refrigerant.
(9) Remove 2 welded pipes of accumulator inlet and outlet.
(10) Remove 2 accumulator leg fixing screws (4 × 10). (See
Photo 16)
Note: Recover refrigerant without spreading it in the air.
Photo 15
Photo 16
15. Removing the reactor (DCL)
(1) Remove the service panel. (See Photo 1)
(2) Remove the top panel. (See Photo 1)
(3) Remove the electrical parts box (See photo 5)
(4) Remove 6 screws (4 x 10) for reactors to remove the
reactors. (See Figure 3)
Figure 3
Compressor
(MC)
Separator
xing screw
Compressor
xing nuts
Separator
Accumulator
Accumulator
leg
Accumulator
leg xing
screws
Reactors
Screws for
reactors
Accumulator
Outlet
Inlet