Magnetic Contactors and Magnetic Starters Magnetic Contactors and Magnetic Starters Exceed your expectations Mitsubishi's Magnetic Contactors and Magnetic Starters, continuously pushing the boundaries. Safety Warning To ensure proper use of the products listed in this catalog, please be sure to read the instruction manual prior to use. Eco Changes is the Mitsubishi Electric , Group s environmental statement, and , expresses the Group s stance on environmental management.
Solve Together Mitsubishi's Magnetic Contactors and Magnetic Starters continue to push the boundaries. MS-A Series Double ratings of AC3 grade (Green) and AC4 grade (Red) were adopted allowing the unit to be downsized. 1933 1953 1960 Mitsubishi Electric began making Magnetic Contactors and Magnetic Starters in 1933 with the first EC Series products. Since then consecutive new products and series have been highly appreciated by our customers.
Desire to down-size the switchboard Desire to reduce the types and stock of switchboard parts Do these requirements sound familiar? The new MS-T Series can help you solve these issues.
There is a saying that "every bit helps" and now with the industries smallest* general purpose Magnetic Contactor in its class, customers are able to more easily down-size their boards than ever before. The perennial issues of remembering to order the terminal covers, fitting them correctly or loosing them in the process are challenges of the past. The integrated terminal cover system means they are always there, on the Magnetic Contactor or its Auxiliary contact, ready to be used.
Easy branch circuit wiring with Manual Motor Circuit Breaker and optional connection conductor unit Easy wiring is available for the new MS-T Series by using the Manual Motor Circuit Breaker and optional connection conductor unit, contributing your productivity improvement. The integrated terminal covers offer various benefits not to mention added protection against electric shock through secure finger protection.
45 55 – – – – – – – – – – – ◇ − ◇ − − ○ ○ ○ − ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ − − ◇ ◇ − ◇ − − ○ ○ − − ○ ○ ○ ○ ○ ○ ○ ○ − − − − − − − − 3-element type MS-□KP ◇ ◇ − ◇ − − ○ ○ ○ − ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ − − Quick motion type MS-□QM − − − − − − − − − − − − − − ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ − − Standard ○ ○ ○ ○ ○ − ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ − − DC operated type MSOD-□ − ◇ ◇ ◇
Making and Breaking capacities S-2×T20 Magnetic Starters Non-Reversing MSO-T10 MSO-T12 MSO-2×T10 MSO-2×T12 MSO-T10KP MSO-2×T10KP Open type (With standard 2-element, Reversing With Thermal Overload Relays) Combined Thermal Overload Relays Magnetic Starters Non-Reversing Open type Reversing S-2×T21 S-2×T25 S-2×T32 MSO-T20 MSO-T21 MSO-T25 – MSO-2×T20 MSO-2×T21 MSO-2×T25 – MSO-T12KP MSO-T20KP MSO-T21KP MSO-T25KP – MSO-2×T12KP MSO-2×T20KP MSO-2×T21KP MSO-2×T25KP – (Three-phas
Specification List Rated voltage and frequency 120 120 470 470 910 910 Model list T18 Frame T25 Appearance Note 1: Add "SA" to the end of the type name to order the operation coil surge absorber mounting type (varistor). Example: S-T10SA AC100V Note 2: Even when the single rating (example: 200V60Hz) is specified for an order, the above rating voltage is indicated on the product.
Connecting electric wire size and operating current Application to standard three-phase motor of Thermal Overload Relays Standard three-phase motor capacity [kW] Thermal Overload Relays Heater Setting range (A) designation (A) Short-circuit protector rating (A) 200-220V 380-440V 0.03 0.05 0.07 0.1 0.05 0.1 TH-T18 TH-T25 Main circuit Auxiliary circuit 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 2 2 2 2 2 4 4 4 6 6 10 10 16 20 20 25 32 50 0.1-0.16 0.14-0.22 0.2-0.32 0.28-0.42 0.4-0.6 0.55-0.85 0.7-1.1 1.
●MSO-T series (non-Reversing) ●MSO-2xT series (Reversing) MSO-T10 MSO-T12 MSO-T20 MSO-T21 MSO-T25 Reversing MSO-2×T10 MSO-2×T12 MSO-2×T20 MSO-2×T21 MSO-2×T25 220 to 240VAC 2.5 3.5 4.5 5.5 7.5 380 to 440VAC 4 5.5 7.5 11 15 500VAC 4 5.5 7.
Contactor Relays Specification List Application 0.12, 0.17, 0.24, 0.35, 0.5, Standard heater rating (designation) (A) 0.7, 0.9,1.3, 1.7, 2.1, 2.5, 3.6, 5, 6.6, 9, 11, 15 Model name SR-T5 Number of poles Contact arrangement 0.24, 0.35, 0.5, 0.7, 0.9, 1.3, 1.7, 2.1, 2.5, 3.6, 5, 6.6, 9, 11, 15, 22 9 5a 9a 4a1b 7a2b 3a2b Rated insulation voltage Rated impulse withstand voltage [kV] 6 Rated frequency [Hz] 50/60 3 51 B 45 63 C 76.
Contact arrangement/Contact placement Model name Model list (for MS-T series) SR-T9 9a 7a2b 5a4b SR-T5 5a 4a1b 3a2b Contact arrangement Model name Type Auxiliary contact blocks UT-AX4 Mounting UT-AX2 * Front clip-on Operation coil surge absorber unit UT-AX11 * UT-SA23 UT-SA21 UT-SA22 UT-SA25 Mounting on top Side clip-on Mechanical interlocks UT-ML11 Side clip-on Operation coil surge absorber With CR A2 A1 13 23 33 43 63 73 83 93 53 Specification/ Function 64 74 84 94 Twin contact
Optional Units ●UT-SA□ Operation Coil Surge Absorber Unit Types and application Number of poles Contact arrangement Front clip-on 4 2 4a 2a 3a1b 1a1b 2a2b Magnetic Contactor Applicable model 2 [kV] 6 50/60 Pollution degree AC120V 6 AC240V 3 (coil load) AC440V 1.5 AC550V 1.2 AC120V 10 Category AC-12 AC240V 8 (resistive load) AC440V 5 AC550V 5 DC24V 3 Varistor SA21 DC48V (large coil load) DC110V 0.6 (2) DC220V 0.3 (0.8) 1.
MEMO ●UT-ML□ Mechanical Interlock Unit Application Applicable magnetic contactor model Specifications UT-ML11 6kV Rated frequency 50/60Hz Pollution degree 3 Terminal screw size/type M3.5 cross slot screw with pressure plate Applicable electric wire size[φmm,mm2] φ1.6 Product Introduction 690V Rated impulse withstand voltage 0.75 to 2.5 Applicable crimp lug size 1.25-3.5 to 2-3.5 Terminal screw tightening torque[N・m] 0.9 to 1.
U.S.A U.S.A. UL standard CSA standard Euro North America GB standard Japan North America CSA standard JIS standards Type International International IEC standard TH-T18KP ■Our standard products comply with the domestic standards as well as various overseas standards and are certified to meet all the standards. Safety certification standard Type IEC EN UL CSA Model name CE Marking Certification body CCC TH-T25KP : JIS EC directive TUV GB (Note1) U.S.A.
Fuse, Class K5 Model Max. Current Ratings Max. Circuit Voltage 600V S.C.P.D. Available Short Circuit Current 600V Circuit Breaker Max. Current Ratings *1 *1 240V 480V S-T10/T12 30A 30A 30A S-T20 70A 50A 50A S-T21 70A 50A 50A 600V 100A 240V N/A 14kA 75A 75A 100A 600V 75A *1 *1 240V 480V 10kA 10kA 600V 10kA 50kA 50kA 50kA S-T32 480V 10kA N/A 75A *1 18kA 10kA 5kA S-T25 Min.
Type Codes * For the information on type codes for orders, check the note in Order Procedure.
Heater designation (setting current) ▲ 3.7kW ▲ 9A ▲ AC200V ▲ AC200V Select from page 16. Refer to page 12,32. Select coil designation from pages 13 and 14 or specify the working operation circuit voltage. Auxiliary contact ▲ 1B Specify the auxiliary contact arrangements. from page 12 Standard (AC operated) Magnetic Contactors ●S-T and S-2XT types Model name S-T20 S-T20 Refer to page 12,32.
Outline Drawing, Contact Arrangement Magnetic Starters 1/L1 3/L2 5/L3 1b 96 21 97 95 98 96 11.6 6 22 2/T1 4/T2 6/T3 10 ●MSO-T12KP ●MSO-T20KP 10 45 79 45 3.9 13 1/L1 3/L2 5/L3 23 89 (Installation Dimension) 84 (Installation Dimension) 8.5 7.5 54 1/L1 3/L2 5/L3 13 A1 L02 R02 14 A2 97 95 2/T1 4/T2 6/T3 98 96 14 3.9 M3.5 screws (Self-lifting) 5 Auxiliary contact 78 Contact arrangement 59 23.
Outline Drawing, Contact Arrangement Magnetic Contactors 3/L2 5/L3 13 28 (Installation Dimension) 3 28 (Installation Dimension) 18 (Internal pitch) 59 M3.5 screws (Self-lifting) 46 21 7.5 4/T2 6/T3 22 23.7 10 78 Auxiliary contact 59 10.5 A2 A1 13 1/L1 3/L2 5/L3 4 21 24 10 78 (10) 1a1b × 2+2b 3.9 8.5 7.5 ●S-2×T21 ●S-2×T25 59 Auxiliary contact 43 31 14 22 2/T1 4/T2 6/T3 6.5 81 63 44 32 3.5 13 59 M3.
Outline Drawing, Contact Arrangement Thermal Overload Relays ●TH-T18KP Installation holes for 2-M4 screws 35 (Installation Dimension) 59 10.5 Resetting bar (Resetting stroke) (2.5mm) 24 Auxiliary contact Operation indication (Manual trip) 23.7 97 95 98 96 TH-T18KP 7.1 2/T1 4/T2 6/T3 6 41.6 30.5 55 For contact arrangement and contact allocation, see Page 22. 75 60 (Installation Dimension) 44.5 Contact arrangement 57 14.5 10.5 10 7.5 8.5 7.5 43 35 M3.
Optional Units ●UT-AX4 Application 17 Magnetic Contactor Applicable model Dimension H S-T10, T12, T20 108 S-T21, T25, T32 111 SR-T5 108 Contact Relay 83 93 64 74 84 94 Magnetic Contactor or Contactor Relay 45 73 25.8 63 Contact arrangement 4a 7.5 8.5 3a1b 2a2b 63 73 83 93 63 71 83 93 63 71 81 93 64 74 84 94 64 72 84 94 64 72 82 94 30 35.5 3 H Note: The contact arrangement 4a is shown in the figure above. ●UT-ML11 M3.
●Tightening torque of mounting screw ●Performance The performance described in this catalog is based on the result of a test conducted under the conditions specified in the Standard (IEC60947-4-1 "Low-voltage switchgear and controller" etc.). If actual use condition is different from this test condition, the user must evaluate the condition (by using an actual device). 1.2 to 1.
Model Standard type Contactor Relays Magnetic Contactors Thermal Overload Relays SR-T5, T9 Terminal dimension and size/type of screw Applicable electric wire size Operating Main circuit [φmm, mm2] circuit cross slot Dimension of Main Operating terminal portion Screw Screw screw with AxBxC circuit circuit type pressure size [mm] (Note 1) plate – – – 7.5×3.7×4.5 M3.5×7.6 cross slot screw with pressure S-T21, T25, T32 10.5×5.2×5.5 M4×10.5 plate TH-T18 cross slot 7.5×4×4 M3.5×7.6 (Load side) screw with 10.
(1) The warranty period for our products shall be one year after purchase or delivery to the designated location. However the maximum warranty period shall be 18 months after production, in consideration that the maximum length of distribution period is to be 6 months after shipping. (2) This warranty period may not apply in the case where the use environment, use conditions, or the number of open/close operation times specifically impact the lives of products.
Solve Together [Related Products] PLC MELSEC-Q Series Universal Model Industry-leading level of high performance servo ◎Realize high-speed, high-accuracy machine control with various iQ Platform compatible controllers and multiple CPUs. ◎Industry-leading level of basic performance: Speed frequency response (2.5kHz), 4,000,000 (4,194,304p/rev) encoder ◎Easily connect to GOTs and Programming tools using built-in Ethernet port.