Instruction manual

29
11
DIP SWITCH FUNCTIONS
DIP SWITCH
Functions
IMP
(IMPEDANCE)
75 / HIGH
TRAP
ON / OFF
MEMORY
FIELD / FRAME
RESERVED
RESERVED
RESERVED
Set to "75
" in normal use.
Set to "HIGH" when making branch connection of a monitor or
other units to the VIDEO IN connector.
Set to "OFF" in normal use.
Set to "ON" when inputting a color signal.
ON : The trap circuit is active.
OFF : The trap circuit is inactive.
FRAME : Set to "FRAME" position in normal use.
FIELD : Set to "FIELD" position to print an image with rapid
motion.
The image displayed on the monitor is usually a single frame
consisting of two fields.
Set to "OFF".
(These switches are not used.)
ON
OFF
DIP SW
DIP SW FUNCTION TABLE
NO. 1 2 3 4 5 6
FUNCTION IMP
TRAP
MEMORY
RESERVED
SW-ON 75 ON FIELD
SW-OFF HIGH OFF FRAME