Air-Conditioners INDOOR UNIT PEA-RP170, 200, 250 WGA GB FOR USER OPERATION MANUAL For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. WT05223X02_cover_only EN 2 08.2.
[Fig. 2.0.1] [Fig. 2.0.2] B C A TEMP. A Air outlet B Air inlet C Air filter 5 ON/OFF A A GB [Fig. 5.0.1] B D C D A Air outlet C Air filter B Air inlet D Air filter handle P E I SW NL F A 2 WT05223X02-illust 2 08.2.
Contents 1. Safety precautions ...................................................................................... 1.1. Installation ................................................................................. 1.2. During operation ........................................................................ 1.3. Disposing of the unit .................................................................. 2. Names and functions of various parts ........................................................ 3.
1.2. During operation In case of failure Warning: Caution: • • • • • Do not use any sharp object to push the buttons, as this may damage the remote controller. Do not twist or tug on the remote controller cord as this may damage the remote controller and cause malfunction. Never remove the upper case of the remote controller. It is dangerous to remove the upper case of the remote controller and touch the printed circuit boards inside. Doing so can result in fire and failure.
3. Operation Remote controller-Button 8 1 9 TEMP. 2 MENU 3 BACK Opening the door. ON/OFF CHECK TEST OPERATION CLOCK 0 FILTER DAY MONITOR/SET PAR-21MAA ON/OFF CLEAR A B C 4 67 0 Filter Down A Test Run button Up B Check button (Clear button) C Airflow Up/Down button Set Temperature buttons 2 Timer Menu button (Monitor/Set button) button ( button) GB 1 5 7 Ventilation button ( Operation button) To next operation number.
When stop continues for 10 minutes, the compressor and indoor fan are operated for 3 minutes to keep the humidity low. For heating E D Press the 2 [operation mode] button to bring up the “ HEAT” display. Regarding displays during heating operation “DEFROST” Displayed only during the defrosting operation. A “STAND BY” Displayed from the start of heating operation until the moment warm air blows out. B ˚C ˚C C SIMPLE TEMP.
Set Time button A to show display 2. or 2. Press the Timer On/Off (Set Day) button 9 to set the day. * Each press advances the day shown at 3 : Sun → Mon → ... → Fri → Sat. 3. Press the appropriate Set Time button A as necessary to set the time. * As you hold the button down, the time (at 4) will increment first in minute intervals, then in ten-minute intervals, and then in one-hour intervals. 5. Press the Mode (Return) button 2 to complete the setting procedure.
Note: Your new entries will be cancelled if you press the Mode (Return) button 2 before pressing the Filter button 4. If you have set two or more different operations for exactly the same time, only the operation with the highest Operation No. will be carried out. 9. Repeat Steps 3 to 8 as necessary to fill as many of the available cells as you wish. 10.Press the mode (Return) button 2 to return to the standard control screen and complete the setting procedure. 11.
Examples If ON and OFF times have both been set at the simple timer, operation and display are as indicated below. Example 1: Start the timer, with ON time set sooner than OFF time ON Setting: 3 hours OFF Setting: 7 hours ON AFTER SIMPLE ▲ At 7 hours after The air conditioner goes off, and will retimer start SIMPLE 5. Press the Mode (Return) button 2 to complete the setting procedure and return to the standard control screen. 6.
3.7. Locking the remote controller buttons (Operation function limit controller) ■ If you wish, you can lock the remote controller buttons. You can use the Function Selection of remote controller to select which type of lock to use. (For information about selecting the lock type, see Installation Manual). Specifically, you can use either of the following two lock types. 1 Lock All Buttons: Locks all of the buttons on the remote controller.
4. The smart way to use Even minimal steps to care for your air conditioner can help make its use far more effective in terms of air-conditioning effect, electricity charges, etc. Prevent intrusion of heat during air-cooling • Set the right room temperature • In cooling operation, a temperature difference of about 5 °C between indoors and outdoors is optimum. • If the room temperature is raised by 1 °C during air-cooling operation, about 10 % electric power can be saved.
6. Troubleshooting Before you call out a repair man, check the following table to see whether there is a simple solution to your problem. ● Unit does not cool very well. • Clean the filter. (Dust and debris that collects in the filter will decrease airflow.) • Check the temperature setting and adjust it if necessary. • Increase the space surrounding the outdoor unit. Is the air intake or air outlet blocked? • Is a window or door open? ● There is a “swishing” noise that occurs from the unit when water flows.
7. Installation and transferring works, and checking Regarding transfer of installation Regarding place for installation Consult with your dealer for details on installation and transferring the installation. • Caution: Never install the air conditioner where there is a risk of leakage of flammable gas. If gas leaks and accumulates around the unit, fire can result.
WT05223X02_ blank 3 08.2.
WT05223X02_ blank 4 08.2.
Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN WT05223X02 WT05223X02_cover_only EN 3 08.2.