Variable Refrigerant Flow Zoning Systems: 3-30 Tons
Mitsubishi Electric is a world leader in all types of quality products. Our consumer products, like high-definition televisions and home theater systems, have won awards for innovation and quality. factories. Quality comes from a company that controls its own research, development, design, materials and manufacturing. From beginning to end, it is all Mitsubishi Electric engineering. It is all about quality.
Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Overview of CITY MULTI® . . . . . . . . . . . . . . . . . . . .
CITY MULTI® VRF (Variable Refrigerant Flow) Zoning Systems: user-friendly ductless, or ducted commercial or residential comfort control systems. CITY MULTI is the first two-pipe, simultaneous cooling and heating system available in the United States and around the world. Our technology has a long and proven track record of quality and reliability.
Easy to install, easier to operate The CITY MULTI Controls Network (CMCN) uses Mitsubishi Electric’s advanced M-NET technology to provide individual, personalized comfort and powerful, centralized control. Each component is integrated onto the secure high-speed communication bus to provide precise temperature control by varying the output of the outdoor unit(s) to match the needs of each zone. CITY MULTI is a simple, two-pipe system with easy, non-polar, two-wire control connections.
CITY MULTI® System Components OUTDOOR UNITS Mitsubishi Electric HVAC has an extensive outdoor unit line-up that can be tailored to any building design need. Choose from modular units that have capacities up to 30 tons for Y-Series heat pump systems or 20 tons for R2-Series heat recovery systems, the Hyper-Heating INVERTER (H2i™) Y-Series units that provides up to 100% heating capacity at -4° F outdoor temperature, single-phase S-Series heat pump, or W-Series water-source units available up to 30 tons.
INDOOR UNITS Mitsubishi Electric’s wide selection of different indoor unit styles allows you to choose the styles and size that meets your requirements for layout and design.
SYSTEM SHOWCASE R2-Series Heat Recovery PURY-P-T/Y(S)JMU-A up to 50 indoor units 208/230V 72k 460V 80k PURY-P72TJMU-A Y-Series Heat Pump PUHY-P-T/Y(S)JMU-A up to 50 indoor units PUHY-P72TJMU-A 208/230V 72k 460V 80k Y-Series H2i® Heat Pump PUHY-HP-T/Y(S)JMU-A PUHY-P72TJMU-A 208/230V 72k 80k TONS 3.5 4 4.
288k SYSTEM COMPONENTS 320k PURY-P96TJMU-A PURY-P240TJMU-A PUHY-P96TJMU-A PUHY-P120TJMU-A 360k 403k 192k 216k 16 20 24 26 30 TONS 192k 240k 288k 312k 360k Btu/h I I I I I 240k 270k 360k 405k Cooling Heating 9
TECHNOLOGY OVERVIEW HIGH PERFORMANCE, MODULAR CITY MULTI® VRF SYSTEMS R2-Series / Y-Series / H2i™ Y-Series CITY MULTI modular outdoor units feature a new modular, design with a smaller installation footprint, low operating sound, easy piping and maintenance, longer line lengths, and light weight. The modular unit design offers greater flexibility in increasing capacity (up to 20 tons with the R2-Series and 30 tons with the Y-Series) while increasing the number of connectable indoor units, to 50.
100% INVERTER-driven, like no other Additional features Adjustable high static pressure, standard When an INVERTER-driven system is operating at partial load, the energy efficiency of the system is significantly higher than that of a standard fixed–speed system. R2-, Y- and H2i™ Y-Series feature adjustable static pressure up to 0.24" W.G., ideal and flexible for any type of application.
LOW AMBIENT COOLING OPTION Mitsubishi Electric is the first and only VRF manufacturer to offer a low ambient cooling solution for its 6–30 ton air source outdoor units. General features Allows system to operate at 100% COOLING capacity at reduced outdoor temperatures: • PUHY Y-Series Outdoor Units – (Now down to -10o FDB Outdoor Temp.) • PURY R2-Series Outdoor Units – (Now down to -10oFDB Outdoor Temp.) • PUHY-HP H2i Y-Series Outdoor Units – (Now down to 0o FDB Outdoor Temp.
LOW AMBIENT SPECIFICATIONS Part # Electrical Net Wt. LAH-1 208/230 1-phase .20 amp 59 lbs. LAH-1 Low Ambient Hood Assembly (slave) combined with the LAH-1 for double fan (XL) modules Controlled by LAH-1 51 lbs. SWD-1 Side Wind Deflector, includes 2 pieces (fits all modules) N/A 45 lbs. RWD-1 Rear Wind Deflector (1 fits S module, 2 fit the XL module) N/A 37 lbs. RWD-2 Rear Wind Deflector (1 fits L Module) N/A 40 lbs.
HIGH EFFICIENCY Mitsubishi Electric HVAC continues to drive acceptance of VRF technology in the U.S. engineering and regulatory arenas. Integrated Energy Efficiency Ratio IEER is the new measure of partial-load cooling performance for unitary equipment and VRF systems. IEER greatly improves the industry methodology for part-load testing by collecting data for four different outdoor testing conditions based on load on the system.
HIGH EFFICIENCY TABLE 1 Electrically Operated Variable Refrigerant Flow Air-to-Air and Applied Heat Pumps–Minimum Efficiency Requirements Equipment Type Size Category <65,000 Btu/h Electric Resistance (or none) VRF Multi-split System 11.0 EER 12.3 IEER 12.9 IEER (as of 7/1/2012) Electric Resistance (or none) VRF Multi-split System with Heat Recovery 10.8 EER 12.1 IEER 12.7 IEER (as of 7/1/2012) ≥135,000 Btu/h and <240,000 Btu/h Electric Resistance (or none) VRF Multi-split System 10.6 EER 11.
R2-SERIES OVERVIEW CITY MULTI® R2-Series: The first two-pipe heat recovery system that simultaneously cools and heats The R2-Series simultaneously cools and heats different zones within a building to provide energy-saving, heat-recovery operation through the use of the BC Controller. The R2-Series can support up to 50 indoor units. Modular units feature low operating sound, easy piping and maintenance design, and are lightweight.
Advantages of CITY MULTI two-pipe systems The advantages of the two-pipe CITY MULTI system become very obvious when it comes to installation. The illustration s below compare the minimum number of connections required for simultaneous cooling and heating system with four indoor units. The CITY MULTI system requires only 20 connections versus 58 for a three-pipe system.
R2-SERIES SPECIFICATIONS 208/230V PURY-P72TJMU-A (-BS) PURY-P96TJMU-A (-BS) PURY-P120TJMU-A (-BS) PURY-P144TJMU-A (-BS) 460V PURY-P72YJMU-A (-BS) PURY-P96YJMU-A (-BS) PURY-P120YJMU-A (-BS) PURY-P144YJMU-A (-BS) BTU / h 72,000 Model Name Power source 208 / 230V, 3-Phase, 60Hz / 460V, 3-Phase, 60Hz Cooling 5.66 7.8 9.99 12.43 17.4 / 15.7 / 7.8 24.0 / 21.7 / 10.8 30.8 / 27.8 / 13.9 38.3 / 34.6 / 17.3 BTU / h 80,000 108,000 135,000 160,000 kW 6.16 8.66 11.02 13.20 A 18.
Model Name 460V PURY-P192TSJMU-A (-BS) *2 PURY-P216TSJMU-A (-BS) *2 PURY-P240TSJMU-A (-BS) *2 PURY-P264TJMU-A (-BS) *2 *5 PURYP288TSJMU-A (-BS) *2 *5 With 1 PURYP72TJMU-A (-BS) and 1 PURY-P96TJMU-A (-BS) *3 With 2 PURYP96TJMU-A (-BS) *3 With 1 PURYP96TJMU-A (-BS) and 1 PURY-P120TJMU-A (-BS) *3 With 2 PURYP120TJMU-A (-BS) *3 With 1 PURYP120TJMU-A (-BS) and 1 PUHY-P144TJMU-A (-BS) *3 With 2 PURYP144TJMU-A (-BS) *3 PURY-P168YSJMU-A (-BS) *2 PURY-P192YSJMU-A (-BS) *2 PURY-P216YSJMU-A (-BS) *2 PU
BC CONTROLLER SPECIFICATIONS for R2-Series and WR2-Series Systems (Heat Recovery) CMB-P-NU-G (Single BC) Specifications Model Name CMB-P105NU-G Number of Branches CMB-P106NU-G 5 CMB-P108NU-G 6 Power Source Power Input Current (208/230V) CMB-P1016NU-G 13 16 Cooling W Heating W Cooling A Heating A Height Inches 11-3/16 73 86 11-3/16 11-3/16 11-3/16 11-3/16 Width Inches 25-17/32 25-17/32 25-17/32 25-17/32 43-1/4 43-1/4 Depth Inches 17-1/32 17-1/32 17-1/32 17-1/32 17-
CMB-P-NU-GB, HB (Sub BC) Specifications Model Name CMB-P104NU-GB Number of Branches 8 16 208/230V, 1-phase, 60 Hz Current (208/230V) Cooling W 53 106 Heating W 27 53 Cooling A Heating A External Finish 314 BC CONTROLLERS Power Input 157 0.25/0.23 0.51/0.46 1.17/1.37 0.13/0.12 0.25/0.23 0.59/0.
Y-SERIES OVERVIEW CITY MULTI® Y-Series: The two-pipe zoned system designed for heat pump operation Y-Series outdoor units are flexible enough to cool or heat up to 50 individual zones, maximizing building design options. They feature low operating sound, easy piping and maintenance design, and light weight. Y-Series units are available in both 208/230V and 460V up to 30 tons for different applications, (6-20 ton units meet ENERGY STAR® Light Commercial Requirements and will exceed proposed ASHRAE 90.
Y-SERIES SPECIFICATIONS PUHY-P72TJMU-A (-BS) PUHY-P96TJMU-A (-BS) PUHY-P120TJMU-A (-BS) PUHY-P144TJMU-A (-BS) 460V PUHY-P72YJMU-A (-BS) PUHY-P96YJMU-A (-BS) PUHY-P120YJMU-A (-BS) PUHY-P144YJMU-A (-BS) BTU / h 72,000 96,000 120,000 5.27 7.95 9.90 12.42 16.2 / 14.6 / 7.3 24.5 / 22.1 / 11.0 30.5 / 27.6 / 13.8 38.3 / 34.6 / 17.3 80,000 108,000 135,000 160,000 5.68 8.54 10.41 13.08 A 17.5 / 15.8 / 7.9 26.3 / 23.8 / 11.9 32.1 / 29.0 / 14.5 40.3 / 36.4 / 18.
Y-SERIES SPECIFICATIONS (continued) PUHY-P168TSJMU-A (-BS) *2 PUHY-P192TSJMU-A (-BS) *2 PUHY-P216TSJMU-A (-BS) *2 PUHY-P240TSJMU-A (-BS) *2 PUHY-P264TJMU-A (-BS) *2 With 1 PUHY-P72TJMU-A (-BS) and 1 PUHYP96TJMU-A (-BS) *3 With 1 PUHY-P72TJMU-A (-BS) and 1 PUHYP120TJMU-A (-BS) *3 With 1 PUHY-P96TJMU-A (-BS) and 1 PUHYP120TJMU-A (-BS) *3 With 2 PUHYP120TJMU-A (-BS) *3 With 1 PUHYP120TSUMU-A (-BS) and 1 PUHY-P144TJMU-A (-BS) *3 PUHY-P168YSJMU-A (-BS) *2 PUHY-P192YSJMU-A (-BS) *2 PUHY-P216YSJMU-A (
Y-SERIES SPECIFICATIONS (continued) PUHY-P312TSJMU-A (-BS) *2 PUHY-P336TSJMU-A (-BS) *2 PUHY-P360TSJMU-A (-BS) *2 With 2 PUHY-P144TJMU-A (-BS) *3 With 1 PUHY-P72TJMU-A (-BS) and 2 PUHY-P120TJMU-A (-BS) *3 With 1 PUHY-P96TJMU-A (-BS) and 2 PUHY-P120TJMU-A (-BS) *3 With 1 PUHY-P96TJMU-A (-BS), 1 PUHY-P120YJUM-A (-BS), and 1 PUHY-P144TJMU-A (-BS) *3 Model Name PUHY-P288YSJMU-A (-BS) *2 PUHY-P312YSJMU-A (-BS) *2 PUHY-P336YSJMU-A (-BS) *2 PUHY-P360YSJMU-A (-BS) *2 460V With 2 PUHY-P144YJMU-A (-BS) *
H2i™ Y-SERIES OVERVIEW Bringing year-round comfort solutions to extreme climates The Hyper-Heating INVERTER (H2i™) technology* is exclusively from Mitsubishi Electric and is available in select CITY MULTI® VRF models. The H2i™ series improves on the Y-Series by providing full heating capacity at 0° F outdoor ambient. H2i™ Y-Series units are available in 208/230V up to 16 tons for different applications (6-16 ton units meet ENERGY STAR® Light Commercial Requirements and will exceed proposed ASHRAE 90.
H2i™ Y-SERIES SPECIFICATIONS PUHY-HP72TJMU-A (-BS) PUHY-HP96TJMU-A (-BS) Power Source Capacity *1 Power Input Current (208/230V) Electrical Supply Btu/h Heating Btu/h Cooling kW 72,000 96,000 80,000 108,000 160,000 216,000 5.60 8.16 11.54 *3 16.81 *3 6.14 8.80 12.65 *3 18.13 *3 A 17.2-15.6 25.1-22.7 35.5-32.1 *3 51.8-46.8 *3 Heating A 18.9-17.1 27.1-24.5 39.0-35.2 *3 55.9-50.
S-SERIES OVERVIEW CITY MULTI® S-Series: Heat Pump solutions for the home or small office The CITY MULTI S-Series is a singlephase heat pump system that is perfect for light commercial or large residential applications. Available in 36,000 or 48,000 Btu/h, the S-Series can provide cooling or heating for up to eight individual zones. The CITY MULTI S-Series provides homes and small offices with all the features and benefits of our large commercial CITY MULTI Y-Series.
S-SERIES SPECIFICATIONS PUMY-P36NHMU(-BS) PUMY-P48NHMU(-BS) Power Source Capacity *1 Power Input Current (208-230V) Electrical Supply 208/230V, 1-phase, 60Hz Cooling Btu/h 36,000 48,000 Heating Btu/h 40,000 54,000 Cooling kW 3.22 4.97 Heating kW 2.93 4.88 Cooling A 14.2/15.7 24.0/21.7 Heating A 12.9/14.2 23.6/21.3 MCA A 26 26 Maximum Fuse Size A 30 30 Type x Quantity Fan Propeller Fan x 2 Airflow Rate CFM Motor Output kW 3,530 0.
W-SERIES OVERVIEW CITY MULTI® W-Series: Modular Water-Source Systems that Simultaneously cool and heat or provide heat pump operation controlled by refrigerant piped between water-source unit, BC controller (R2-Series) or manifold (Y-series) and indoor units. W-Series systems can be designed with a wide selection of indoor model configurations and controllers.
Extended temperature range The updated WR2 and WY series CITY MULTI water source units can now handle entering water temperatures down to 23oF in both heating and cooling mode allowing more possibilities for geothermal applications. Coupling the water source units with a geothermal loop will not only provide the benefit of higher efficiencies by using a lower entering water temperature, but will also provide all the benefit of an inverter driven CITY MULTI system.
W-SERIES SPECIFICATIONS WR2-Series Heat Recovery Water-source Unit (Requires BC Controller - refer to specifications on pages 20 - 21) Model Name 208/230V PQRY-P72THMU-A PQRY-P96THMU-A PQRY-P120THMU-A 460V PQRY-P72YHMU-A PQRY-P96YHMU-A PQRY-P120YHMU-A Power source 208 / 230V, 3-Phase, 60Hz / 460V, 3-Phase, 60Hz Cooling Capacity (Nominal) *1 Heating Electrical Supply BTU / h 72,700 96,300 kW 3.97 5.77 7.73 A 12.6 / 11.4 / 5.7 17.9 / 16.2 / 8.1 23.6 / 21.4 / 10.
WR2-Series Heat Recovery Water-source Unit (continued) (Requires BC Controller - refer to specifications on pages 20 - 21) 208/230V Model Name PQRY-P144TSHMU-A *2 PQRY-P168TSHMU-A *2 With 2 PQRY-P72THMU-A *3 With 1 PQRYP72THMU-A and 1 PQRY-P96THMU-A *3 PQRY-P192TSHMU-A *2 PQRY-P216TSHMU-A *2 PQRY-P240TSHMU-A *2 With 1 PQRY-P96THMU-A With 2 PQRY-P96THMU-A With 2 PQRY-P120THMU-A and 1 PQRY-P120THMU-A *3 *3 *3 PQRY-P144YSHMU-A *2 PQRY-P168YSHMU-A *2 460V With 2 PQRY-P72YHMU-A *3 With 1 PQRYP72YHM
W-SERIES SPECIFICATIONS (continued) WY-Series Heat Pump Water-source Unit Model Name 208/230V PQHY-P72THMU-A PQHY-P96THMU-A PQHY-P120THMU-A 460V PQHY-P72YHMU-A PQHY-P96YHMU-A PQHY-P120YHMU-A Power source 208 / 230V, 3-Phase, 60Hz / 460V, 3-Phase, 60Hz Cooling Capacity (Nominal) *1 Heating Electrical Supply BTU / h 72,700 96,000 kW 3.85 5.61 7.51 A 12.2 / 11.0 / 5.5 17.4 / 15.8 / 7.8 22.9 / 20.8 / 10.3 BTU / h 80,000 108,000 135,000 kW 3.83 6.18 7.62 A 11.8 / 10.7 / 5.
WY-Series Heat Pump Water-source Unit (continued) 208/230V Model Name 460V PQHY-P144TSHMU-A *2 PQHY-P168TSHMU-A *2 PQHY-P192TSHMU-A *2 PQHY-P216TSHMU-A *2 PQHY-P240TSHMU-A *2 With 2 PQHY-P72THMU-A *3 With 1 PQHY-P72THMU-A and 1 PQHY-P96THMU-A *3 With 2 PQHYP96THMU-A *3 With 1 PQHY-P96THMU-A and 1 PQHYP120THMU-A *3 With 2 PQHYP120THMU-A *3 PQHY-P144YSHMU-A *2 PQHY-P168YSHMU-A *2 PQHY-P192YSHMU-A *2 PQHY-P216YSHMU-A *2 PQHY-P240YSHMU-A *2 With 2 PQHYP96YHMU-A *3 With 1 PQHY-P96YHMU-A and 1 P
W-SERIES SPECIFICATIONS (continued) WY-Series Heat Pump Water-source Unit (continued) PQHY-P264TSHMU-A *2 208/230V Model Name PQHY-P336TSHMU-A *2 PQHY-P360TSHMU-A *2 With 1 PQHY-P96THMU-A and 2 PQHY-P120THMU-A *3 With 3 PQHYP120YHMU-A *3 PQHY-P312YSHMU-A *2 PQHY-P336YSHMU-A *2 PQHY-P360YSHMU-A *2 With 2 PQHY-P96YHMU-A and 1 PQHY-P120YHMU-A *3 With 1 PQHY-P96YHMU-A and 2 PQHY-P120YHMU-A *3 With 3 PQHYP120YHMU-A *3 PQHY-P312TSHMU-A *2 With 1 PQHY-P72THMU-A With 2 PQHY-P96THMU-A With 3 PQHY-P96T
PWFY OVERVIEW (Hydronic Heat Exchanger) Hot and cold water, quickly and efficiently. PWFY: Hydronic Heat Exchanger The PWFY Hydronic Heat Exchanger is available in two configurations, the HEX (-AU) and the Booster (-BU). Each provides unique solutions to incorporate into an existing VRF system for an efficient means to heat and cool water.
PWFY OVERVIEW (continued) Sample Hotel Cooling And Hot Water Demand Per Hour 14000 Cooling Load (BTUH) 12000 Hot Water Load (BTUH) Load (BTUH) 10000 8000 6000 4000 2000 0 12:00 AM 4:00 AM 8:00 AM 12:00 PM 4:00 PM 8:00 PM Time Of Days This graph shows a sample hourly cooling and hot water demand load profile for a high-rise hotel building.
PWFY-P-NMU-E-AU/BU SPECIFICATIONS Model Name PWFY-P36NMU-E-AU PWFY-P72NMU-E-AU Power Source PWFY-P36NMU-E-BU 208/230V, 1-phase, 60Hz Cooling Capacity *1 Btu/h 36,200 72,000 - Heating Capacity *1 Btu/h 39,900 79,800 39,900 Power Consumption Current Cooling W 15 N/A Heating W 15 2,480 Cooling A 0.072 / 0.065 N/A Heating A 0.072 / 0.065 12.30 /11.12 External Finish Dimensions Net Weight Galvanized-steel Sheet Height In. Width In. 17-3/4 Depth In.
CITY MULTI® INDOOR UNITS Multiple choices for indoor units In today’s modern building practices, interior mechanical components are designed for ultimate comfort and functionality. Aesthetics are also important. CITY MULTI VRF systems offer many sleek styles of ductless or ducted indoor units for various applications. Each indoor unit gives you ultimate in zoning flexibility in each space. All are compatible with R2-Series, Y-Series, H2i™ Y-Series, W-Series and S-Series outdoor units.
PVFY: Vertical-concealed The PVFY vertical air handler is designed for closet or attic applications. The side drain pan makes it possible to use in a horizontal, left facing, position. With all the components, including a linear expansion valve (LEV) and controls pre-mounted within the cabinet for easy installation, this unit is ideally suited for use in retrofit and new building applications. Its available in capacities of 12,000, 18,000, 24,000, 30,000, 36,000, 48,000 and 54,000 Btu/h.
PKFY OVERVIEW (wall-mounted) Elegant design and compact dimensions ideal for offices, classrooms, and residential uses. Capacity range: 6,000 to 30,000 Btu/h A wide selection for your design and performance needs Whatever the size or shape of your room, there is a Mitsubishi Electric PKFY unit that is just right, delivering the style and performance you demand and deserve. PKFY units mount high on the wall and blend beautifully into any space.
PKFY-P-N*MU-E SPECIFICATIONS Model Name PKFY06NBMU-E PKFYP08NBMU-E PKFYP12NHMU-E Power Source PKFYP15NHMU-E PKFYP18NHMU-E PKFYP24NKMU-E PKFYP30NKMU-E 208 / 230V, 1 Phase, 60Hz Cooling Capacity Btu/h *1 6,000 8,000 12,000 15,000 18,000 24,000 30,000 Heating Capacity Btu/h *1 6,700 9,000 13,500 17,000 20,000 27,000 34,000 Power Consumption Current External Finish Dimensions Net Weight Cooling W 30 40 60 Heating W 30 40 60 Cooling A 0.15 0.30 0.29 0.
PLFY OVERVIEW (ceiling-recessed) Perfect airflow to meet your needs with four-way control. Ceiling applications The PLFY-NBMU has a unit height of only 10-1/4" or 11-3/4", depending on the model. It provides great looking installations in low-ceiling areas with very 10 1/4" or 113/4" limited space. PLFY-NBMU PLFY-NCMU Capacity range: 12,000 – 36,000 Btu/h The PLFY-Series indoor unit offers unequaled flexibility of installation. This compact ceiling-recessed design makes it easy to install and operate.
Corner-pocket design simplifies maintenance and installation Easy maintenance, long-life filter The washable filter provides about 2,500 hours of use in a normal office environment before cleaning is needed. The PLFY-NBMU is also available with an optional multifunction casement that allows for additional ventilation air and better filtration. PLFY-NBMU allows access through the pockets equipped on each of four corners of the grille to complete installation, maintenance work, and height adjustment.
PLFY-P-NBMU-E SPECIFICATIONS Model Name PLFY-P12NBMU-E PLFY-P15NBMU-E Power Source PLFY-P18NBMU-E 208/230V, 1-phase, 60Hz Cooling Capacity Btu/h *1 12,000 15,000 18,000 Heating Capacity Btu/h *1 13,500 17,000 20,000 50 Power Consumption Current Cooling W 30 40 Heating W 20 30 40 Cooling A 0.22 0.29 0.36 Heating A 0.14 0.22 0.29 External Finish Color (Munsell No.) Dimensions Net Weight *2 Grille 6.4Y 8.9/0.
PLFY-P-NCMU-E SPECIFICATIONS Model Name PLFY-P08NCMU-E Power Source Cooling Capacity Heating Capacity Power Consumption Current PLFY-P12NCMU-E Btu/h *1 8,000 12,000 Btu/h *1 9,000 13,500 50 60 Heating W 50 60 Cooling A 0.23 0.28 Heating A 0.23 0.28 Grille: White (6.4Y 8.9/0.
PMFY OVERVIEW (ceiling-recessed cassette) Compact and lightweight one way airflow, perfect for limited ceiling space applications. Capacity range: 6,000 – 15,000 Btu/h Ideal for small spaces The PMFY model is a one-way, ceiling-recessed cassette unit perfect for shallow ceiling spaces. The PMFY unit moves air in one direction and can introduce ventilation air. It is designed especially for use in areas like hotel rooms which cannot support duct work or lack sufficient space to allow for wallmounted units.
PMFY-P-NBMU-E SPECIFICATIONS Model PMFY-P06NBMU-E PMFY-P08NBMU-E Power Source PMFY-P12NBMU-E PMFY-P15NBMU-E 208/230V, 1 Phase, 60Hz Cooling Capacity Btu/h *1 6,000 8,000 12,000 15,000 Heating Capacity Btu/h *1 6,700 9,000 13,500 17,000 50 Power Consumption Cooling W 40 40 40 Heating W 40 40 40 50 Cooling A 0.20 0.20 0.21 0.26 Heating A 0.20 0.20 0.21 0.26 Current External Finish Dimensions Net Weight *2 Grille: Munsell 0.98Y 8.99/0.
to increase efficiency and increase the time span between service calls. The PCFY-Series is perfect for restaurants, kitchens, and other larger commercial spaces where ovens and other equipment add to an PCFY OVERVIEW (ceiling-suspended) already taxed cooling or heating load. PCFY-P-NGMU-E Compact design ideal for classrooms, restaurants, The ceiling-suspended compact dimensions areideal idealfor forrestaurant, restaurants and stores. Ceiling-suspended type's compact dimensions stores uses and stores.
PCFY SPECIFICATIONS Model Name PCFY-P15NKMU-E PCFY-P24NKMU-E Power Source PCFY-P30NKMU-E PCFY-P36NKMU-E 208 / 230V, 1 Phase, 60Hz Cooling Capacity Btu/h *1 15,000 24,000 30,000 36,000 Heating Capacity Btu/h *1 17,000 27,000 34,000 40,000 110 Power Consumption Current Cooling W 30 40 90 Heating W 30 40 90 110 Cooling A 0.35 0.41 0.83 0.97 Heating A 0.35 0.41 0.83 0.97 External Finish Munsell No.
PEFY OVERVIEW (ceiling-concealed) Flexible design allows elegant interior layout. Designed to be neither seen nor heard, just to perform The PEFY model is a high-performance, ceiling-concealed, ducted indoor unit. In fact, if it weren’t for the constantly comfortable environment this unit delivers, you might not even know it was there. The ducted fan coils are designed to be installed above the ceiling, hidden from public view. And it's extremely quiet, with sound ratings as low as 22 dB(A).
PEFY-P-NMHU-E SPECIFICATIONS Model Name ALTERNATE HIGH STATIC OPTION PEFY-P15NMHU-E PEFY-P18NMHU-E PEFY-P24NMHU-E Power Source PEFY-P27NMHU-E PEFY-P30NMHU-E 208/230V, 1-phase, 60Hz Cooling Capacity *1 Btu/h 15,000 18,000 24,000 27,000 30,000 Heating Capacity *1 Btu/h 17,000 20,000 27,000 30,000 34,000 Power Consumption Current Cooling W 188/207 188/207 245/270 270/297 326/360 Heating W 188/207 188/207 245/270 270/297 326/360 Cooling A 0.96/1.06 0.96/1.06 1.25/1.
PEFY-P-NMAU-E SPECIFICATIONS (Medium static) Model Name PEFY-P06NMAU-E PEFY-P08NMAU-E PEFY-P12NMAU-E Power Source PEFY-P15NMAU-E PEFY-P18NMAU-E PEFY-P24NMAU-E 208 / 230V, 1 Phase, 60Hz Cooling Capacity Btu/h *1 6,000 8,000 12,000 15,000 18,000 24,000 Heating Capacity Btu/h *1 6,700 9,000 13,500 17,000 20,000 27,000 Power Consumption Cooling W 60 90 110 120 Heating W 40 70 90 100 Current Cooling A 0.56 0.66 0.67 0.77 1.04 Heating A 0.45 0.55 0.56 0.66 0.
FBM SERIES FILTER BOXES GENERAL FEATURES Designed for CITY MULTI • All filter boxes include 2" thick pleated MERV 13 filter(s) installed FBM Series Filter Boxes PEFY-P-NMAU-E Medium-Static - Rated MERV 13 when tested in accordance Designed for CITY MULTI PEFY-P-NMAU-E Medium-Static Indoor Units with ANSI/ASHRAE 52.2 Standard Indoor Units ® ¨ - Rated Class 2 under U.L. Standard 900 Job Name: No.
PEFY-P-NMSU-E SPECIFICATIONS Model Name PEFY-P06NMSU-E* 1 LOW PROFILE PEFY-P08NMSU-E Power Source Btu/h Heating Capacity *2 Current 6,000 8,000 12,000 Net Weight 13,500 18,000 17,000 24,000 6,700 9,000 20,000 27,000 50/50 60/60 70/70 90/90 120/120 Heating W 30/30 40/40 50/50 70/70 100/100 Cooling A 0.42/0.41 0.51/0.49 0.56/0.53 0.57/0.55 0.74/0.70 0.98/0.93 Heating A 0.32/0.31 0.41/0.39 0.46/0.43 0.47/0.45 0.64/0.60 0.88/0.
FBL SERIES FILTER BOXES GENERAL FEATURES Designed for CITY MULTI® PEFY-P-NMSU-E Low Profile Indoor Units • All filter boxes include 1" thick pleated MERV 8 filter(s) installed • Rated MERV 8 when tested in accordance with ANSI/ASHRAE 52.2 Standard • • Rated Class 2 under U.L.
PFFY OVERVIEW (floor-standing) Effective use of perimeter space. Concealed Type PFFY-P-NEMU-E Concealed Type Compact unit provides simple, effective air-conditioning in perimeter zones Less than nine inches deep, these PFFY floor-standing units are easy to install in peripheral spaces, yet offer highly efficient air-conditioning performance. Since these are floor-standing models, they are perfect for spaces with little or no ceiling space.
PFFY-P-NEMU/NRMU-E SPECIFICATIONS PFFY-P-NEMU-E Model Power Source Cooling Capacity Heating Capacity Power Cooling Consumption Heating Current Cooling Heating External Finish (Munsell No.
PVFY OVERVIEW (vertical-concealed) Ideal for closet or attic applications. Vertical Airflow Capacity range: 12,000 – 54,000 Btu/h The Vertical Air Handler The PUFY Vertical Air Handler is ideal for installations in closets or equipment rooms where space is limited. It also has a side drain pan allowing it to be installed in a horizontal left position. The vertical air handler can be connected to a system with all other CITY MULTI indoor units for complete system design flexibility.
PVFY-P-E00A SPECIFICATIONS Model Name PVFY-P12E00A PVFY-P18E00A PVFY-P24E00A Power Source PVFY-P30E00A PVFY-P36E00A PVFY-P48E00A PVFY-P54E00A 54,000 208/230V, 1-phase, 60Hz Cooling Capacity Btu/h *1 12,000 18,000 24,000 30,000 36,000 48,000 Heating Capacity Btu/h *1 13,500 20,000 27,000 34,000 40,000 54,000 60,000 Power Consumption Current Dimensions Net Weight Cooling kW 0.17 / 0.17 0.28 / 0.28 0.26 / 0.26 0.38 / 0.38 0.32 / 0.32 0.36/0.36 0.41/0.41 Heating kW 0.
CITY MULTI® CONTROLS NETWORK Our CITY MULTI Controls Network makes it easy to manage your building The CITY MULTI Controls Network (CMCN) manages up to 2,000 indoor units from a single networked PC–operation, monitoring, scheduling (daily, weekly, and yearly), error email, personal browser, tenant billing, and maintenance diagnostic information. The CMCN puts individual, personalized comfort in the hands of the tenants and the building manager.
CITY MULTI® CONTROLS NETWORK iPhone Screen Shots iPhone Mobile Application The meZO (Mitsubishi Electric Zone) controller App allows for the monitoring and controlling of Mitsubishi Electric HVAC systems. This level of access can be utilized by building or campus managers, maintenance personnel, building owners and homeowners to name a few. meZO can control CITY MULTI® systems and Mr.
CENTRALIZED CONTROLLER AG-150 Option: Black surface cover. PAC-YG71CBL M-NET AG-150 PAC-SC51KUA ETHERNET DIDO Board 79 ˚F 79 ˚F 82 ˚F Function Description Touch Screen 9" high resolution color touch screen Max No.
CENTRALIZED CONTROLLER GB-50ADA DIDO Board ETHERNET 79 ˚F 79 ˚F 82 ˚F Description Max No. of Indoor Units Up to 50 indoor units can be connected ON/OFF On/Off operation for a single group and batch operation Operation Mode Cool/Dry/Auto/Fan/ Heat.
CENTRALIZED CONTROLLER TC-24 TC-24 66 PAC-SC51KUA DIDO Board Function Description Max No. of Indoor Units Up to 24 indoor units can be connected ON/OFF On/Off operation for a single group and batch operation Operation Mode Cool/Dry/Auto/Fan/ Heat/Setback.
CENTRALIZED CONTROLLER GB-24 GB-24 PAC-SC51KUA DIDO Board ETHERNET 79 ˚F 79 ˚F 82 ˚F Description Max No. of Indoor Units Up to 24 indoor units can be connected ON/OFF On/Off operation for a single group and batch operation Operation Mode Cool/Dry/Auto/Fan/ Heat/Setback.
CONTROLS NETWORK SPECIFICATIONS Local remote controller Model PAR21MAA Controlable Grougs/Indoors (Groups/Indoors) 1 / 16 AG-150 50 / 50 PAR-F27MEA PAC-Y151CRB PAR-FL32MAA 1 / 16 1 / 16 1 / 16 AG-150 GB-50ADA 50 / 50 AG-150 GB-24 Browser *4 GB24 24 / 24 GB24 TC-24 Browser *7 TG-2000 *4*5 2000 / 2000 Operating ON/OFF Mode(cool/heat/dry/fan) N N Temperature N N Local Permit/Prohibit N N N N
SOFTWARE OPTIONS FOR CENTRALIZED CONTROLLERS The Centralized Controllers support operations that supersede control of the remote controllers and include system configuration, daily/weekly scheduling, operation, and malfunction monitoring. All Centralized Controllers are equipped with an RJ-45 Ethernet port to support interconnection with a networked PC via a closed/direct Local Area Network (LAN).
UP TG-2000™ INTEGRATED SYSTEM SOFTWARE The TG-2000 integrated system software enables the user to control multiple AG-150/GB-50ADA controllers and provide enhanced functions from a single, dedicated networked PC configured with the TG-2000 software and AG-150/GB-50ADA software licenses. The TG-2000 configured PC is capable of controlling up to 2,000 indoor units with the AG-150/GB-50ADA Centralized Controllers.
I/O CONTROL BOARD ETHERNET AG150 PAC-YG66DCA PAC-YG63DCA ! EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2 PAC-YG66DCA Digital Input Digital Output (DIDO) Control Board The DIDO controller used in conjunction with a AG-150, GB-50ADA, GB-24 or TC-24 Centralized Controller can control and monitor third–party general equipment.
CITY MULTI® CONTROLLERS Deluxe MA Remote Controller (PAR-21MAA) • Features user-friendly multilingual operation and monitoring • Controls up to 16 indoor units in a single group • User Functions: Allows user to set: - On/Off - operation modes of Cool, Heat, Dry, Fan, or Auto (R2-Series only), ventilation - set temperature from 57° F – 87° F, depending on operation mode and indoor unit Example - fan speed setting - airflow direction • Timer Operation: Supports Weekly Timer operation (On/Off/Set Temperature
CITY MULTI® CONTROLLERS Wireless MA Remote Controller (PAR-FL32MA) and Receiver (PAR-FA32MA) • Features user-friendly operation and monitoring • Controls up to 16 indoor units in a single group • User Function: Allows user to set: • Grouping: Can be used only in same group with PAC-YT51 (Simple MA Remote Controller), PAR-21MAA (Deluxe MA Remote Controller), and other PAR-FL32MA (Wireless MA Remote Controllers) - On/Off • Addressing: No addressing required - operation modes of Cool, Heat, Dry, Fan or Au
SYSTEM INTEGRATION: LONWORKS® AND BACNET® The CMCN supports integration with Building Management Systems (BMS) via our LonWorks® and BACnet® interfaces. LonWorks® Interface The Mitsubishi Electric HVAC LonWorks® interface, LMAP03U, supports up to 50 indoor units with a variety of network variables on a per indoor unit basis. Input variables include, but are not limited to: On/Off, Operation Mode, Fan Speed, Prohibit Remote Controller, and Filter Sign Reset.
LOSSNAY ENERGY® RECOVERY VENTILATORS Lossnay energy recovery ventilators provide outdoor air solutions for indoor environmental quality. See the Lossnay Technical Brochure for complete information.
LOSSNAY ENERGY® SPECIFICATIONS Model Name LGH-F300RX3-E Power supply LGH-F470RX3-E Single-phase 208/230V 60Hz Single-phase 208/230V 60Hz Fan Speed Extra high High Low Extra high High Current (A) 1.3 1.1 0.6 2.5 2.4 1.7 Power consumption (W) 278 260 146 560 525 375 Air volume (CFM) 300 300 180 470 470 380 External static pressure (in. H2O) 0.65 0.10 0.02 0.96 0.78 0.
Ceiling suspension fixture pitch Dimensions Model Nominal diameter A B C D E F LGH-F300RX3-E 34-15/16 40 12-1/2 31-1/8 41-1/4 1-9/16 LGH-F470RX3-E 45-13/16 39-1/2 15-11/16 40-9/16 40-13/16 LGH-F600RX3-E 45-13/16 48-7/16 15-11/16 40-9/16 49-3/4 Duct connecting flange Duct pitch Weight G H J K ø8 ø7-9/16 ø8-3/16 29-5/16 4-7/8 73 lb 3/8 ø10 ø9-1/2 ø10-3/16 27-3/16 5-7/8 143 lb 3/8 ø10 ø9-1/2 ø10-3/16 36-3/16 5-7/8 159 lb Position where duct direction chan
VENTILATION: Dedicated Outdoor Air Systems Dedicated Outdoor Air System (DOAS) without reheat and with with reheat The PEFY-AF Dedicated Outside Air System comes in two configurations, the CFM and the CFMR. Both configurations offer a high capacity coil that will condition incoming outside air, making it suitable to be distributed to down–stream fan coil units.
Model PEFY-AF1200CFM PEFY-AF1200CFMR Power Source 208/230V, 1-phase, 60Hz Cooling Capacity *1 Btu/h 112,000 112,000 Heating Capacity *1 Btu/h 61,400 61,400 Btu/h - Reheat Capacity Power Consumption Current 24,200 Cooling W 660 / 780 Heating W 660 / 780 Cooling A 3.19 / 3.45 Heating A 3.19 / 3.45 Height In. 18-9/16 Width In. 49-1/4 Depth In.
MAINTENANCE TOOL SOFTWARE OVERVIEW Mitsubishi’s easy-to-use, Windows® based Maintenance Tool software allows technicians to monitor and collect CITY MULTI system data and control various functions of the system for maintenance purposes. System monitoring is accomplished through direct connection between your PC and the M-NET bus line using the MN-Converter or by connecting remotely to a system centralized controller, such as the AG-150 or GB-50ADA via a TCP/IP network, or via a remote dialup connection.
MAINTENANCE TOOL SOFTWARE OVERVIEW The system connection information view shows a snapshot of the components connected to the system, identifying each component’s type and system address. Through a simple series of clicks, the user can monitor the critical data points for each component, manipulate the control features and operate each component, or view each component’s malfunction log.
DESIGN TOOL SOFTWARE OVERVIEW Mitsubishi’s Design Tool software makes designing with CITY MULTI quick and easy. The designer just needs to drag and drop components to complete the design. The program has built–in safeguards against exceeding limitations and shows if there is an error. Assuring line lengths, maximum connected capacities, component selection, control scheme, etc. are within the system requirements.
DESIGN TOOL SOFTWARE OVERVIEW The system is summarized in an Excel (.xls) file. Included are all the design parameters, equipment lists, line sizes, indoor unit operating capacities, additional refrigerant based on line lengths, control scheme with addressing and much, much more. The Excel-based output simplifies quoting a job and tracking equipment lists. SOFTWARE With the help of AutoCAD* or AutoCAD LT* installed on the computer, a schematic (.
Mitsubishi Electric Air Conditioning & Refrigeration Systems Works acquired ISO 9001 certification under Series 9000 of the international Standard Organization (ISO), based on a review of quality warranties for the production of refrigeration and air conditioning equipment. ISO Authorization System The ISO 9000 series is a plant authorization system relating to quality warranties as stipulated by the ISO.