Contents 1. 2. 3. 4. 5. 6. Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Parts Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Screen Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Setting the Day of the Week and Time . . . . . . . . . . . . . . . . . . . . . . . 6 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.
2. Parts Names ■ Wired Remote-Controller “Sensor” indication Display Section For purposes of this explanation, all parts of the display are shown. During actual operation, only the relevant items will be displayed. Identifies the current operation Displayed when the remote controller sensor is used. Day-of-Week Shows the current day of the week. Time/Timer Display “Locked” indicator Shows the current time, unless the simple or Auto Off timer is set.
2. Parts Names ■ Wireless Remote-Controller Transmission area Transmission indicator Remote controller display Timer indicator *For explanation purposes, all of the items that appear in the display are shown. *All items are displayed when the Reset button is pressed.
3. Screen Configuration Function Selection of remote controller For details on setting the language for the remote controller display, refer to section 8. Function Selection. The initial language setting is English. ● Function Selection of remote controller: Set the functions and ranges available to the remote controller (timer functions, operating restrictions, etc.) ● Set Day/Time: Set the current day of the week or time.
5. Operation 5.2. Mode select ■ Press the operation mode ( 5.3. Temperature setting ) button 2 and select the opera- tion mode 2.
5. Operation 5.5. Airflow direction setting 5.6. Ventillation (PCA-KA, PKA-HAL) ■ With the unit running, press the Airflow Up/Down button 6 as necessary. • Each press changes the direction. The current direction is shown at 6. • The change sequence and the available settings are as follows. Remote controller For LOSSNAY combination 5.6.1. For Wired Remote-controller To run the ventilator together with the indoor unit: Press the ON/OFF button 1.
6. Timer 2. Press the Timer Menu button 2, so that the “Set Up” appears on the screen (at 2). (Note that each press of the button toggles the display between “Set Up” and “Monitor”.) 3. Press the Timer On/Off (Set Day) button 9 to set the day. Each press advances the display at 3 to the next setting, in the following sequence: “Sun Mon Tues Wed Thurs Fri Sat” → “Sun” → ... → “Fri” → “Sat” → “Sun Mon Tues Wed Thurs Fri Sat”... 4.
6. Timer 4 2 Press the Timer On/Off button 9 so that the timer setting no longer appears on the screen (at 7). Timer Setting Hr 3 ON AFTER SIMPLE 1 Action (On or Off) * “— —” is displayed if there is no setting. 7 ˚C ˚C 1. Be sure that you are at a standard control screen, and that the simple timer indicator is visible in the display (at 1).
6. Timer 6.1.3. Auto Off Timer ■ This timer begins countdown when the air conditioner starts and shuts the air conditioner off when the set time has elapsed. down the Timer On/Off button 9 for 3 seconds so that “Timer Off” appears (at 6) and the timer value (at 7) disappears. ● Hold ■ Available settings run from 30 minutes to 4 hours in 30-minute intervals. Note: *1. Weekly Timer/Simple Timer/Auto Off Timer cannot be used at the same time. *2.
7. Other Functions 7.1. Locking the Remote Controller Buttons (Operation function limit controller) ■ If you wish, you can lock the remote controller buttons. You can use the Function Selection of remote controller to select which type of lock to use. (For information about selecting the lock type, see section 8, item [2] (1)). Specifically, you can use either of the following 2 lock types. 1.
8. Function Selection Function selection of remote controller The setting of the following remote controller functions can be changed using the remote controller function selection mode. Change the setting when needed. Item 1 Item 2 Item 3 (Setting content) 1. Change Language (“CHANGE LANGUAGE”) Language setting to display • Display in multiple languages is possible 2.
8. Function Selection [Function selection flowchart] Setting language (English) Normal display (Display when the air conditioner is not running) Hold down the button and press the button for 2 seconds. Press the operation mode button. Press the TIMER MENU button. Press the TIMER ON/OFF button. Hold down the button and press the button for 2 seconds. Remote controller function selection mode Item 1 Change Language Item 2 English Dot display Germany Spanish TEMP.
8. Function Selection [Detailed setting] [4]-1 CHANGE LANGUAGE setting The language that appears on the dot display can be selected. • Press the [ MENU] button G to change the language. 1 English (GB), 2 German (D), 3 Spanish (E), 4 Russian (RU), 5 Italian (I), 6 Chinese (CH), 7 French (F), 8 Japanese (JP) Refer to the dot display table. [4]-2 Function limit (1) Operation function limit setting (operation lock) • To switch the setting, press the [ ON/OFF] button D.
8.
9. Emergency Operation for Wireless Remote-controller Starting operation • To operate the cooling mode, press the seconds. • To operate the heating mode, press the seconds. Stopping operation • To stop operation, press the than 2 seconds. button D for more than 2 button C for more than 2 button D or the button C for more [Fig.
10. Care and Cleaning ■ PCA-RP·KA ■ PCA-RP·HA A B D C 1 Open the intake grille. 2 Hold the knob on the filter then pull the filter up in the direction of an arrow. To replace the filter after cleaning, be sure to insert the filter far enough until it fits into the stopper. A Filter B Intake Grille C Knob D Stopper RP71 → 3 pieces RP125 → 4 pieces D ►Cleaning the oil filter (PCA-RP·HA Series) 1) Removing the oil filter 1 Remove the filter by sliding it in the direction of an arrow.
11. Trouble Shooting Having trouble? Air conditioner does not heat or cool well. Here is the solution. (Unit is operating normally.) ■ Clean the filter. (Airflow is reduced when the filter is dirty or clogged.) ■ Check the temperature adjustment and adjust the set temperature. ■ Make sure that there is plenty of space around the outdoor unit. Is the indoor unit air intake or outlet blocked? When heating operation starts, warm air does not blow from the indoor unit soon.
11. Trouble Shooting Having trouble? Draining water or motor rotation sound is heard. Here is the solution. (Unit is operating normally.) ■ When cooling operation stops, the drain pump operates and then stops. Wait approximately 3 minutes. ■ The indoor operation sound level is affected by the acoustics of the Noise is louder than specifications. particular room as shown in the following table and will be higher than the noise specification, which was measured in anechoic room.
12. Specifications Model PSA-RP71GA PSA-RP100GA PSA-RP125GA PSA-RP140GA Power source(voltage /Frequency) Rated Input(Indoor only) Rated Current(Indoor only) Heater Dimension(Height) Dimension(Width) Dimension(Depth) Fan airflow rate(Low-High) Noise level(Low-High) Net weight ~/N 230/50 0.15/0.15 0.66/0.66 - 0.24/0.24 1.06/1.06 - 0.28/0.28 1.23/1.23 - 0.36/0.36 1.59/1.