Engineering Manual

Decoration panel PLP-40EAU
How to Use / How to Install
1. Checking the contents (Fig. 1)
This kit contains this manual and the following parts.
Accessory name Q’ty Remarks
1
Grille
1
950 × 950 (mm), 37-3/8 × 37-3/8 (inch)
2
Installation gauge
1
(Divided into 4 parts)
3
Screw (4 × 16)
1
For PLP-40EAU, PLP-40EAEU
2. Preparing to attach the grille (Fig. 2)
With the gauge 2 supplied with this kit, adjust and check the positioning of the
main unit relative to the ceiling surface. If the main unit is not properly positioned
relative to the ceiling surface, it may allow air leaks or cause condensation to
collect.
Make sure that the opening in the ceiling is within the following tolerances:
860 × 860-910 × 910 mm, 33-7/8 × 33-7/8 to 35-13/16 × 35-13/16 inch
Make sure that A is performed within 17-22 mm, 11/16 to 7/8 inch. Damage could
result by failing to adhere to this range.
A Main unit
B Ceiling surface
C Installation gauge 2 (inserted into the main unit)
D Ceiling opening dimensions
2.1. Removing the intake grille (Fig. 3)
Slide the levers in the direction indicated by the arrows 1 to open the intake
grille.
Unlatch the hook that secures the grille.
* Do not unlatch the hook for the intake grille.
With the intake grille in the “open” position, remove the hinge of the intake grille
from the grille as indicated by the arrows 2.
2.2. Removing the corner panel (Fig. 4)
Loose the 4 screws on the corner. Slide the corner panel in the direction of the
arrow 1 in the gure and remove the corner panel.
[Fig. 3] [Fig. 4]
A Intake grille
B Grille 1
C Intake grille levers
D Grille hook
E Hole for the grille’s hook
F Corner panel
G Screw
H Detail
3. Selection of air outlets
For this grille the discharge direction is available in 11 patterns. Also, by setting
the remote controller to the appropriate settings, you can adjust the air-ow and
speed. Select the required settings from the Table 1 according to the location in
which you want to install the unit. (More than two directions must be selected.)
1) Decide on the discharge direction pattern.
2) Be sure to set the remote controller to the appropriate settings according to
the number of air outlets and the height of the ceiling on which the main unit
will be installed.
Notes:
• Whenchangingthenumberofdirections,youneedanairoutletshutter
plate,whichisoptionalpart.
• Donotselect2directionsinahotandhumidenvironment.(Dewformation
ordewdropmayresult.)
4. Installing the grille
4.1. Preparations (Fig. 5)
Make sure to ip 2 hooks on the grille up.
A
D
A=11/16
+3/16
0
B
C
Fig. 3
Fig. 2
Fig. 4
Fig. 1
Fig. 5
4-directional 3-directional
Blowout
direction
patterns
1 pattern: initial setting
4 patterns:
one air outlet fully closed
2-directional
Blowout
direction
patterns
6 patterns:
2 air outlet fully closed
Table 1
C
A
B
E
D
2
2
F
B
1
F
G
H
G
<Hook is in the lowered position><Hook is in the raised position>
1 2