Engineering Manual

PAC-SH91MK-E/PAR-SA92MW-E/PAR-SL93B-E
Other function selections
Now that you know how to change LOSSANY connectivity setting, there are several other settings that can be changed as well.
The following table lists the various settings that can be changed through the remote controller and the default settings.
*1
*1
PCA-A·KA
Function
Settings
Not available
Available
Indoor unit operating average
Set by indoor unit’s remote controller
Remote controller’s internal sensor
Not supported
Supported (indoor unit is not equipped with outdoor-air intake)
Not supported (indoor unit is not equipped with outdoor-air intake)
Energy saving cycle automatically enabled
Energy saving cycle automatically disabled
100Hr
2500Hr
No filter sign indicator
Quiet
Standard
High ceiling
No vanes
Equipped with vanes (No.1 set)
Equipped with vanes (No.2 set)
Power failure automatic recovery
Indoor temperature detecting
LOSSNAY connectivity
Auto mode (only for PUZ)
Filter sign
Fan speed
Up/down vane setting
Table 3.
*1 Power failure automatic recovery initial setting depends on the connecting outdoor unit.
Things to remember when entering function selections:
The basic procedure for entering function selections is the same as described for switching between LOSSNAY connectivity.
However, there are some differences at step 2 for selecting the unit number, step 3 for selecting the mode number
and step 4 for selecting the setting number.
The following Tables 4 and 5 list the various function settings, mode numbers and setting numbers.
Table 4 details the function of the entire refrigerant system while Table 5 shows the function that can be set for
the indoor unit.
Table 4. Itemized functions of the entire refrigerant system (select unit number 00)
Mode
01
02
03
05
Mode no.
Settings
Not available
Available (Approximately 4-minutes wait-period after
power is restored.)
Indoor unit operating average
Set by indoor unit’s remote controller
Remote controller’s internal sensor
Not supported
Supported (indoor unit is not equipped with outdoor-air intake)
Not supported (indoor unit is not equipped with outdoor-air intake)
Energy saving cycle automatically enabled
Energy saving cycle automatically disabled
Power failure
automatic recovery
Indoor temperature
detecting
LOSSNAY
connectivity
Auto mode
(only for PUZ)
Setting no.
Check
Remarks
1
2
1
2
3
1
2
3
1
2
Approximately 4-minutes wait-
period after power is restored.
Table 5. Itemized functions of the indoor unit (select unit numbers 01 to 02 or 07)
Mode
Settings
100Hr
2500Hr
No filter sign indicator
Quiet
standard
High ceiling
No vanes
Equipped with vanes (No.1 set)
Equipped with vanes (No.2 set)
07
08
11
Mode no.
Filter sign
Fan speed
Up/down vane
setting
Setting no.
Check
Remarks
1
2
3
1
2
3
1
2
3
264