5 UTILITY PACKAGE (GX Configurator-DA)
(4) Write the offset/gain setting values to the module
Write the offset/gain settings to the D/A converter module with the following
procedure after completing the settings for all channels using the user range
setting. Note that if settings are written while offset/gain settings are incomplete, the
status at that point will be written to the module.
(a) Write to the D/A converter module
Select "Write requested" from the setting value field for the offset/gain setting
write request, and then click on the Execute test
button.
(b) Confirm execution of write operation
Confirm that the present value field display for the offset/gain module write
request changes from "Write request" to "No write request".
(c) Error handling
Confirm that the ERROR LED for the D/A converter module is off. If the
ERROR LED is lit, click on Close
, check the error code on the monitor
screen, and then perform the offset/gain settings again.
5.6.4 Pass data (Q62DA/Q64DA)
Perform operation in the following sequence to save/restore the user range.
(1) Switch to the pass data screen
Perform the operation in Section 5.6.1 to display the Pass data screen.