User`s manual
4 - 21
4.7 Setting Packets
1
OVERVIEW
2
COMMON OPERATIONS
FOR INTELLIGENT
FUNCTION MODULES
3
OPERATING
INTELLIGENT
FUNCTION MODULES
4
PREDEFINED
PROTOCOL SUPPORT
FUNCTION
A
APPENDIX
I
INDEX
Conversion
Variable
For 'Fixed Number of Data', display the address range of a
device or buffer to be specified as a variable with [ ].
For 'Variable Number of Data', additionally display the starting
address of a device or buffer memory which specifies the data
length with another [ ].
Fixed Number of Data: [D1-D2]
Variable Number of Data: [D1] [D2-D11]
Display "Conversion" using elliptical expressions.
HEX -> ASCII Decimal : -> Dec
HEX -> ASCII Hexadecimal : -> Hex
ASCII Decimal -> HEX : Dec ->
ASCII Hexadecimal -> HEX : Hex ->
-> Hex
Fixed number of data/Variable number of data Variable Number
Display "Number of data" using elliptical expressions. Number of data (3)
Number of digits of data Digit (3)
Display a blank-padded character (0/Space). Padded (0)
Display the conversion unit using elliptical expressions.
Word : Word
Double Word : Double
Double
Display whether signed or not.
Unsigned
Signed
Signed
When 'Signed' is selected in "Sign", display the sign character
using elliptical expressions.
None : none
+ : +
0 : 0
Space :space
Sign character (none)
Display the number of decimals using elliptical expressions. Decimal point (5)
Display the delimiter using elliptical expression.
No Delimiter : none
Comma : comma
Space : space
Delimiter (comma)
Check Code
Range for calculation of a check code Object element2-7
Display the processing method using elliptical expressions.
Horizontal Parity : Parity
Sum Check : Sum check
16-bit CRC (for MODBUS) : CRC MOD
Parity
Display "Code Type" using elliptical expressions.
ASCII Hexadecimal : Hexadecimal
ASCII Decimal : Decimal
HEX : HEX
Hexadecimal
Display the complement calculation using elliptical expressions.
No Complement Calculation : No calculation
One's Complement : 1 complement
Two's Complement : 2 complement
1 complement
Display the data flow using elliptical expressions.
Forward Direction (Upper Byte -> Lower Byte) : Forward
Reverse Direction (Lower Byte -> Upper Byte) : Reverse
Byte Swap (by Word) : Byte
Forward
Data size 2Byte
Non-verified
Reception
(Receive only)
Display the check size with ( ). ("Variable" is displayed when the
set value is '0'.)
(123Byte)
Element type Display content Display example