User`s manual
4 - 26
4.7.2 Setting elements
4 PREDEFINED PROTOCOL SUPPORT FUNCTION
GX Works2
■ Setting of check code
Configure the check code setting.
Screen display
Select "Check Code" on the Add New screen.
Operating procedure
• Set the items on the screen.
Item Description
Element Name Set a name of the element.
Processing Method Select a calculating method.
Code Type
*1
Select a send/receive format of the check code.
Data Length
*1
Select the data length on the line.
Data Flow
*1
Select the sequence of data when "Data Length" is other than '1'.
Complement
Calculation
*1
Select a type of complement calculation.
Calculating Range
(Start)/Calculating
Range (End)
Select element numbers for the start and end of the calculating range.
*1 : Not settable when "Processing Method" is '16-bit CRC (for MODBUS)'.