User`s manual
2 - 4
2.1.1 Adding intelligent function module data
2 COMMON OPERATIONS FOR INTELLIGENT FUNCTION MODULES
GX Works2
● Switch setting
The switch setting of the intelligent function module is reflected to the "Switch Setting" on the <<I/O Assignment>>
tab of the PLC parameter.
● Changing the positioning data display range
The display range of the positioning data can be changed by the following setting.
Select [Tool] ⇒ [Options] ⇒ "Intelligent Function Module" ⇒ "QD75/LD75 Type Positioning", and make settings for
"Display Specification of Positioning Data".
If the display range is enlarged by setting "Display specification of positioning data", it takes longer time to display
the positioning data editing window.
When positioning data No.101 and above are not necessary, select "Data No.1 to 100".
● Display when mismatches of data assignment exist between PLC parameters and intelligent function
module data
When mismatches of data assignment exist between the I/O assignment setting of the PLC parameter and the
intelligent function module data, the icon in the Project view is displayed as shown below.
● Opening project data which contain modules not supported by this version
When project data which contain an intelligent function module not supported by this version are opened,
"Reserved Module" is displayed in the tree of the Project view.
It cannot be edited, displayed, or printed, however, it can be saved in the project. In addition, its intelligent function
module parameters can be written to the programmable controller CPU.
(Example of display in the Project view)
<Normal display> <Duplicate display>