User`s manual
2 - 6
2.1.2 Setting intelligent function module data
2 COMMON OPERATIONS FOR INTELLIGENT FUNCTION MODULES
GX Works2
■ Switch settings
Edit the switch setting of the intelligent function module.
Screen display
Select Project view ⇒ "Intelligent Function Module" ⇒ "(module)" ⇒ "Switch Setting".
Operating procedure
1. Set the items on the screen
For details of the setting items, refer to the manual of each intelligent function module.
• The available choices can be displayed in a combo box by double-clicking the cell.
2. Click the button
This setting is applied to the switch setting on the <<I/O Assignment>> tab of the PLC parameter.
The switch setting set on the <<I/O Assignment>> tab of the PLC parameter is also applied to this
setting.
● Adjusting height/width of data table when characters are illegible
Height and width of cells can be adjusted by selecting [View] ⇒ [Automatic Adjustment for Height]/[Automatic
Adjustment for Width].
The adjusted height and width are saved to the project.
● Switching display on the setting screen of serial communication module.
The display can be switched to either string or hexadecimal format by selecting [View] ⇒ [String/Hexadecimal
Switch Format] on the User Register Frame Content
screen.
● Switch setting data not supported by this version
To set the switch setting data not supported by this version, do it in the switch setting under <<I/O assignment>> in
the PLC parameter.