User`s manual

2 - 22
2.4.1 Registering and monitoring intelligent function modules
2 COMMON OPERATIONS FOR INTELLIGENT FUNCTION MODULES
GX Works2
2.4 Monitoring Intelligent Function Modules
This section explains how to monitor input/output signals and buffer memory of an intelligent function module.
For QD75/LD75 positioning module, this function is used to debug a program such as ladder. For checking an
operation of QD75/LD75 positioning module or debugging, use the positioning monitor.
( Section 3.5.1)
2.4.1 Registering and monitoring intelligent function modules
Register and monitor module information of an intelligent function module.
Screen display
Select [View] [Docking Window] [Intelligent Function Module Monitor] [Intelligent Function Module
Monitor 1] to [Intelligent Function Module Monitor 10].
Displa
y
contents
Operating procedure
1. Register the intelligent function module to be monitored.
For the registration method, refer to Section 2.4.2.
2. Select [Online] [Watch] [Start Watching].
The current values of the registered intelligent function module are displayed in the window.
Item Description
Item
Display the name of the module information.
When "Data Type" is 'Detail Dialog' ( )/'Error Code' or 'Warning Code' ( ), an icon is displayed at
the head of each item.
Current value
Display the current value of the module information.
Display character strings such as ON/OFF.
Device Display the device assigned to the module information.
Data Type
Display the data type of the module information.
For 'Detail Dialog'/'Error Code'/'Warning Code', details of each item can be confirmed.
For details, refer to the Point in this section.