User`s manual

3.5.2 Positioning test
3 - 23
3.5 QD75/LD75 Positioning Module
1
OVERVIEW
2
COMMON OPERATIONS
FOR INTELLIGENT
FUNCTION MODULES
3
OPERATING
INTELLIGENT
FUNCTION MODULES
4
PREDEFINED
PROTOCOL SUPPORT
FUNCTION
A
APPENDIX
I
INDEX
Positioning start test
Perform the test operation by specifying a positioning data number or a point number of block start
data.
Operating procedure
1. Select "Positioning start signal" for "Select Function" on the Positioning Test
screen.
2. Set the items on the screen.
Item Description
Start Type Select a start type for the test operation.
Positioning Start Signal Select this to perform the positioning start.
Positioning Data No. Set a positioning data number.
Block Start Select this to perform the block start.
Block No. Set a block number.
Point No. Set a point number.
Multiple Axes Simultaneous Start Select this to perform the multiple axes simultaneous start.
Multiple Axes Simultaneous
Positioning Start Data No.
Set positioning data numbers for each axis.
Step Check this to perform the step start, and select the step mode.
External Command Validates a speed-position switch and/or a position-speed switch.
External Command Valid Check this to validate external commands.
Speed-position Switching Enable
Flag
Check this to validate the external command of speed-position switch.
Position-speed Switching Enable
Flag
Check this to validate the external command of position-speed switch.