Installation Instructions
-
43
-
'13 • SRK-T-144
4. ELECTRICAL WIRING WORK For details of electrical cabling, refer to the indoor unit installation manual.
H
05
R
N
R
4or5
G
1.5
Harmonized cable type
300/500 volts
Natural-and/or synth. rubber wire insulation
Polychloroprene rubber conductors insulation
Stranded core
Number of conductors
One conductor of the cable is the earth conductor
(yellow/green)
Section of copper wire (mm
2
)
H05RNR4G1.5 (Example) or 245IEC57
Electrical installation work must be performed by an electrical installation service provider qualified by a power provider of the country.
Electrical installation work must be executed according to the technical standards and other regulations applicable to electrical installations in the country.
t Do not use any supply cord lighter than one specified in parentheses for each type below.
t braided cord (code designation 60245 IEC 51)
t ordinary tough rubber sheathed cord (code designation 60245 IEC 53)
t flat twin tinsel cord (code designation 60227 IEC 41)
Use polychloroprene sheathed flexible cord (code designation 60245 IEC57) for supply
cords of parts of appliances for outdoor use.
t Ground the unit. Do not connect the grounding wire to a gas pipe, water pipe, lightning rod
or telephone grounding wire.
If improperly grounded, an electric shock or malfunction may result.
t A grounding wire must be connected before connecting the power cable. Provide a
grounding wire longer than the power cable.
t The installation of an impulse withstanding type earth leakage breaker is necessary. A
failure to install an earth leakage breaker can result in an accident such as an electric shock
or a fire.
t Do not turn on the power until the electrical work is completed.
t Do not use a condensive capacitor for power factor improvement under any circumstances.
(It dose not improve power factor, while it can cause an abnormal overheat accident)
t For power supply cables, use conduits.
t Do not lay electronic control cables (wireless remote control and signaling wires)
and other cables together outside the unit. Laying them together can
result in the malfunctioning or a failure of the unit due to electric noises.
t Fasten cables so that may not touch the piping, etc.
t When cables are connected, make sure that all electrical components
within the electrical component box are free of loose connector coupling
or terminal connection and then attach the cover securely. (Improper
cover attachment can result in malfunctioning or a failure of the unit, if
water penetrates into the box.)
t Never use a shield cable.
t SRC-ZMXA-S complies with the DRED (Demand Response Enabling
Devices) standard AS/NZS4755.3.1 and supports demand response
modes 1, 2, and 3 (DRM1, 2, and 3). Since the air conditioner limits the
electric power or energy by receiving the DRED input signal, the sense
of cooling operation or heating operation may deteriorate over time. The
outdoor unit of this air conditioner is equipped with a terminal block for
DRED input and supports ELV (Extra-Low Voltage) complying with
AS/NZS60335.1.
CAUTION
Use cables for interconnection wiring to avoid loosening of the
wires. CENELEC code for cables Required field cables.
In case of faulty wiring connection, the indoor unit stops,
and then the run lamp turns on and the timer lamp blinks.
Clearance
3. DRAIN PIPING WORK
t Execute drain piping by using a drain elbow and drain grommets
supplied separately as accessories, where water drained from
the outdoor unit is a problem.
t Water may drip where there is a larger amount of drain water.
Seal around the drain elbow and drain grommets with putty or
adequate caulking material.
t Condensed water may flow out from vicinity of service valve
or connected pipes.
t Where you are likely to have several days of sub-zero
temperatures in a row, do not use a drain elbow and drain
grommets. (There is a risk of drain water freezing inside and
blocking the drain.)
t When condensed water needs to be led to a drain, etc., install the unit
on a flat base (supplied separately as an optional part) or concrete
blocks.
Then, please secure space for the drain elbow and the drain hose.
Do not put a grommet on
this hole.
This is a supplementary
drain hole to discharge
drain water, when a large
quantity of it is gathered.
Drain elbow
Grommet
Drain hose
(To be procured on the installer’s part)
CAUTION