High Performance Air Conditioning SR series Residen t i a l A i r C o n d i t i o n e r s
Wall Mounted type SRK COP 5.
ficiency and reliability logy. Floor Standing type SRF COP 4.
High Efficiency The industry’s highest EER COP levels The ZIX, ZG and ZE series clear the 2010 MEPS. EER in Cooling COP in Heating 5.71 5.20 5.5 5.0 4.5 4.14 4.0 5.5 3.33 5.26 5.0 3.42 3.23 3.33 4.48 4.5 2.93 3.85 3.5 5.56 4.44 4.07 4.0 3.82 3.62 2.93 3.5 3.21 3.0 3.0 2.5 2.
High Efficiency Our Latest Technologies New propeller fan Silicon-coated PCB The new propeller fan was carefully matched with a fan motor in order to keep the same capacity as that of previous models with less electrical consumption. In synergy with the leaf shape grill has seen an improvement of energy efficiency by 5% and a decrease of sound level.(SRC50/60ZIX-S) The printed circuit board of the outdoor unit is coated by silicon. The coating ensures longevity of the board in humid conditions.
Airflow 3D AUTO Vertical + Horizontal AIR SCROLL 3 motors make 3 independent controls Programmed air distribution Applied models 3D AUTO 3D AUTO is a one touch programme. Three motors (one vertical working motor + two horizontal working motors) make three independent air flow controls. The airflow is uniform, quiet and reaches at long distance from the indoor unit.
Airflow Applied models All SRK, SKM Aircraft technology was used in the design of the air conditioner’s airflow system Jet Air Scroll Long Reach & Silent Air Flow We used the same aerodynamic analysis technology as used in developing jet engines. CFD (computational fluid dynamics) is used for blade shape design and air channels for jet engines. The same technology has been used in our air conditioners.
Clean Air Generates the same amount of negative ions as a forest environment Applied models All SRK, SKM 24-hour ION The air conditioner body has a tourmaline coated sheet. Negative ions (2,500 -3,000/cc) are generated even when the air conditioner is not running, allowing you to experience them without incurring any electrical cost.
Clean Air This is the original and only technology to control the temperature and humidity for inactivating allergens Allergen Clear Filter Sterilization Mechanism Enzyme + Urea deactivates allergens and kills bacteria Urea H2N- Enzyme Slack of high order structure Reduction in a molecule -COOH Protein structure of allergen A molecule is decomposed Rate of inactivation against allergens collected on the filter 93.
Advanced Technology Anti-microbial specifications and design will deliver cleanliness and safety Applied models Anti-microbial indoor fan All SRK, SKM Anti-microbial treatment Anti-microbial indoor fan The indoor fan has undergone anti-microbial treatment to resist growth of mould and germs. Mould creating odours which can occur when an air conditioner is not in operation are prevented. ·Intestinal bacteria (Escherichia coli IFO 3972) ·Staphylococcus aureus subsp.
Advanced Technology Applied models SRK-ZIX, SRK-ZE, SRK-ZG, SCM-ZG SRF-ZIX Wide Operation Range Heating and cooling operations are possible at an outdoor temperature as low as –15°C -15°C Our new advanced technology has improved the heating and cooling operation range. Units can be installed when heating or cooling operation is required at low ambient conditions down to -15°C.
Product line up R410A Model SRK-ZIX series SRF-ZIX series Floor Standing type 2.5 20ZIX-S 25ZIX-S 35ZIX-S 50ZIX-S 25ZIX-S 35ZIX-S 50ZIX-S 2.8 6.3 7.1 7.5 8.0 63ZE-S1 71ZE-S1 80ZE-S2 80ZE-S1 NEW 60ZIX-S NEW HEAT PUMP DC INVERTER Capacity Range (kW : Rated cooling capacity) 3.5 4.0 5.0 6.0 2.0 SRK-ZE series SRK-ZG series 20ZG-S Model SKM 25ZG-S 35ZG-S 2.0 2.2 2.5 2.8 3.5 20ZG-S 22ZG-S 25ZG-S 28ZG-S 35ZG-S 4.0 4.5 4.8 5.0 5.6 6.0 6.3 7.1 8.
Functions Filter Allergen Filter SUN Filter Allergen Clear Filter The filter breaks down the pollen, lice, and all allergens that live on cat skins, etc. and deactivates them. Enzyme Filter Photocatalytic Washable Deodorizing Filter Natural Enzyme Filter Enzymes used in the filter are naturally occurring lytic enzymes which attack cell walls of microorganisms trapped on the filter and destroy them. It keeps air fresh by deodorizing the molecules causing odor.
INVERTER HEATPump PUMPModel MODEL(High (HighCOP) COP) Inverter Heat SRK-ZIX series NEW R410A SRK20ZIX-S, SRK25ZIX-S, SRK35ZIX-S SRK50ZIX-S, SRK60ZIX-S SRC20ZIX-S, SRC25ZIX-S, SRC35ZIX-S SRC50ZIX-S, SRC60ZIX-S FUNCTION Allergen SUN Comfortable Functions Comfortable Air Flow Functions Auto Flap Memory UP/DOWN Lateral Filter Filter Convenient & Economy Functions Economy OFF Timer Sleep On Timer 24h Timer DRY Others Back-up Auto Switch Restart Swing Auto Refrigerant pipe length Positioning of
High Efficiency Industry leading COP levels Our new models, SRK20/25/35ZIX-S have reached perhaps the highest level of COP (coefficient of performance) in the industry. There was a full model change both of indoor and outdoor units. Our advanced technologies have been applied to our larger models: SRK50/60ZIX-S. 6.0 5.5 5.71 5.41 5.45 5.56 6.0 5.5 6.0 5.00 5.20 5.08 5.26 5.0 5.0 5.0 4.5 4.5 4.5 4.0 4.0 4.0 3.5 3.5 SRK20ZIX-S CURRENT NEW 5.5 4.02 4.14 4.20 4.48 3.
INVERTER HEATPump PUMPModel MODEL(High (HighCOP) COP) Inverter Heat SRF-ZIX series SRC25ZIX-S, SRC35ZIX-S R410A SRC50ZIX-S NEW SRF25ZIX-S, SRF35ZIX-S, SRF50ZIX-S The highest COP level in the industry EER in Cooling Our experience, research and development efforts with the floor standing series have enabled us to reach the highest COP level in the industry. All models clear the 2010 MEPS level by a wide margin.
High Efficiency Sophisticated Design With a classy semi flat front panel in chic white, the new series fits in all kinds of rooms and creates a relaxing atmosphere. Choice of wall hanging, floor standing or behind gallery installation is available. Quiet Operation The optimum balance of air outlet direction and sufficient air flow volume means the sound level has been minimized. The level of SRF25ZIX-S in the cooling lo mode is only 26dB(A).
Inverter Heat Pump Model (High COP) SRK-ZE series R410A SRK63ZE-S1, SRK71ZE-S1 SRK80ZE-S1, SRK80ZE-S2 Refrigerant pipe length Maximum pipe length SRC63ZE-S1, SRC71ZE-S1 SRC80ZE-S1, SRC80ZE-S2 30m FUNCTION Allergen SUN Maximum height difference 20m Comfortable Functions SRK63ZE-S1, SRK80ZE-S1 SRK71ZE-S1, SRK80ZE-S2 Filter Filter Comfortable Air Flow Functions Auto Flap Memory UP/DOWN Lateral Convenient & Economy Functions Economy OFF Timer Sleep Swing On Timer 24h Timer DRY Maintenance &
Inverter Heat Pump Model SRK-ZG series R410A SRK20ZG-S, SRK25ZG-S SRK35ZG-S Refrigerant pipe length SRC20ZG-S, SRC25ZG-S SRC35ZG-S Maximum pipe length 15m Maximum height difference FUNCTION Allergen SUN 10m Comfortable Functions SRK20ZG-S, SRK25ZG-S SRK35ZG-S Filter Filter Comfortable Air Flow Functions Auto Flap Memory UP/DOWN Lateral Swing Auto Positioning of installation Convenient & Economy Functions Economy OFF Timer Sleep DRY On Timer 24h Timer Maintenance & Prevention Functions S
Inverter Multi-Split Model Inverter Multi-split System R410A The multi-split system allows a single outdoor unit to service up to four indoor unit configurations. Three different styles of indoor units can connect to a line up of 5 multi circuited outdoor units from 4.0kW to 13.5kW.
High Efficiency OUTDOOR UNIT SCM40ZG-S, SCM45ZG-S SCM48ZG-S, SCM60ZG-S SCM80ZG-S ■ CONNECTION OF REFRIGERANT PIPING Limit The maximum permissible length & height of the indoor and outdoor units and associated refrigerant piping is shown below.
Inverter Multi-Split System Multi System INDOOR UNIT R410A Wall mounted type SKM series FUNCTION Enzyme SUN Comfortable Functions Filter Filter Comfortable Air Flow Functions Auto Flap Memory UP/DOWN Lateral Swing Auto Positioning of installation Convenient & Economy Functions Quiet OFF Timer Sleep Maintenance & Prevention Functions Self Detachable Diagnostic MC On Timer 24h Timer DRY Others Back-up Auto Switch Restart 24h ION Luminous SPECIFICATIONS Item Cooling capacity Heating capacity
High Efficiency Ceiling Concealed type SRRM series FUNCTION Comfortable Functions Convenient & Economy Functions On Timer Quiet OFF Timer 24h Timer DRY Maintenance & Prevention Functions Others Back-up Self Auto Diagnostic Switch Restart MC SPECIFICATIONS Model Item Cooling capacity Heating capacity ISO-T1 ISO-T1 Cooling Heating Cooling Heating Cooling Heating Sound power level * Sound pressure level * Air flow Q’ty (Hi) Exterior dimensions(HXWXD) Net weight Piping OUTDOOR UNITS TO BE COMBINED SRR
Control Option Control option Wired remote control can be connected interface Model Interface SRK63/71/80ZE-S1/2 SKM60/71ZG-S SRRM, STM not required SRK20~50ZG-S SKM20~50ZG-S SRK20~60ZIX-S SRF25~50ZIX-S Remote Control RC-E1R SC-BIK1-E SC-BIKN-E RC-E3 Can be connected to SUPERLINK- II Model SRK20~60ZIX-S SRF25~50ZIX-S Interface SC-BIKN-E SC-ADN-E Remote Control RC-E3 RAC series RAC series (SRK20~60ZIX-S) SC-BIKN-E (SRF25/35/50ZIX-S) PAC VNV series SC-BIKN-E SC-SL2N-E RC-E3 RC-E3 RC-E3
High Dimensions Efficiency Dimensions INDOOR UNIT Unit: mm Wall mounted type SRK20ZIX-S SRK25ZIX-S SRK35ZIX-S SRK50ZIX-S SRK60ZIX-S SRK63ZE-S1 SRK71ZE-S1 SRK80ZE-S1 SKM60ZG-S SKM71ZG-S SRK80ZE-S2 881.9 4 21 19 (right,left)61.5 3 248 1098 3 Piping hole right (left) Piping hole right Terminal block 9 9 48 3.1 309 43.5 318 220 890 4 64 55 61.5 46.5 1098 51.2 55 60 60 46.5 61.5 26 Terminal block 122.
Dimensions High Efficiency Dimensions INDOOR UNIT Unit: mm 4way ceiling cassette type STM25ZF-S STM35ZF-S STM50ZF-S STM60ZF-S 570 243 104 Celling opening 660 (For conventional celling) Hanging bolt pitch 530 D B PANEL E A 35 45 or more Hanging bolt pitch 530 350 319 197 137 93 196 250 C 68 541 Hanging fixture 202 *Please arrange VP25 connector sockets on the installer's part.
High Efficiency OUTDOOR UNIT Unit: mm SRC20ZG-S SRC25ZG-S SRC35ZG-S Drain holes(ø20) 12 111.4 99.4 290 312.5 350 43.1 23.5 50 313.1 104.9 2-16x12 510 780 14 349.5 439.1 165.1 18.9 61.9 Terminal block Service valve (Liquid) 138.4 Flare connection ø6.35 (1/4'') 95.9 14 40 40 42.5 540 33.5 Service valve (Gas) Flare connection ø9.52 (3/8'') SRC63ZE-S1 SRC71ZE-S1 SRC80ZE-S1 SRC80ZE-S2 532 19 Drain holes 61 150 580 2-ø15 25.8 150 880 19 61 418 380 15 340 47.5 223 60 29.
Cool Only Wall Split System SRK-CHVA series SRK10CHVA Refrigerant pipe length Maximum pipe length 15m SRC10CHVA Maximum height difference 10m SRK10CHVA FUNCTION Comfortable Functions Enzyme SUN Filter Filter Comfortable Air Flow Functions Auto Flap Memory UP/DOWN Convenient & Economy Functions On Timer OFF Timer Sleep 24h Timer DRY Maintenance & Prevention Functions Self Detachable Diagnostic MC Others Back-up Auto Switch Restart 24h ION Luminous ■ SPECIFICATIONS Model o pera ti onal da
Other Products FD series - Inverter Packaged System FDTC FDE FDUM FDT FDC FDU KX6 M series - VRF Inverter Multi System FDCKXEN6 1ø 11.2, 14.0 & 15.5kW (heat pump only) FDCKXES6 3ø 22.4, 28.0 & 33.5kW • 11.
Before starting use Heating performance Refrigerant leakage Indication of sound values Use in snowy areas The heating performance values (kW) described in catalog are the values obtained by operating at an outdoor temperature of 7 C and indoor temperature of 20 C as set forth in the ISO Standards. As the heating performance decreases as the outdoor temperature drops, if the outdoor temperature is too low and the heating performance is insufficient, use other heating appliances as well.