Operation Manual

17
8.Installation,relocationandinspection
Warning:
Iftheairconditioneroperatesbutdoesnotcoolorheat(dependingonmodel)theroom,consultyourdealersincetheremaybearefrigerant
leak.Besuretoasktheservicerepresentativewhetherthereisrefrigerantleakageornotwhenrepairsarecarriedout.
Therefrigerantchargedintheairconditionerissafe.Refrigerantnormallydoesnotleak,however,ifrefrigerantgasleaksindoors,andcomes
intocontactwiththereofafanheater,spaceheater,stove,etc.,harmfulsubstanceswillbegenerated.
Electricalwork
Provide an exclusive circuit for power supply of the air conditioner.
Be sure to observe the breaker capacity.
Warning:
• Thecustomershouldnotinstallthisunit.Iftheunitisinstalledincorrectly,re,electricshock,injuryduetoafallingunit,waterleakage,etc.
mayresult.
• Donotconnectusingbranchedoutletoranextensioncord,anddonotattachmanyloadstooneelectricoutlet.
Areorelectricshockmayresultfrompoorcontact,poorinsulation,exceedingthepermissiblecurrent,etc.
Consultyourdealer.
Caution:
• Applygrounding
Donotconnectagroundingwiretoagaspipe,waterpipe,lightningrodorgroundwireofatelephone.
Ifagroundingisincorrect,itmaycauseanelectricshock.
• Installanearthleakagebreakerdependingontheplacewheretheairconditioneristobeinstalled(humidplace,etc.).
Iftheearthleakagebreakerisnotinstalled,itmaycauseanelectricshock.
Inspectionandmaintenance
When the air conditioner is used for several seasons, the capacity may be lowered due to dirt inside the unit.
Depending upon the conditions of use, an odor may be generated or dirt, dust, etc. may prevent proper drainage.
It is recommended to apply inspection and maintenance (charged) by a specialist in addition to normal maintenance. Consult your dealer.
Alsoconsideroperationsound
Do not put an object around the air outlet of the outdoor unit. It may cause lowering of capacity or increase operating sound.
If abnormal sound is heard during operation, consult your dealer.
Relocation
When the air conditioner is to be removed or reinstalled because of rebuilding, moving, etc., special techniques and work are required.
Warning:
Repairorrelocationshouldnotbedonebythecustomer.
Ifthisisdoneincorrectly,itmaycauseare,electricshock,injurybydroppingoftheunit,waterleakage,etc.Consultyourdealer.
Disposal
To dispose of this product, consult your dealer.
Ifyouhaveanyquestion,consultyourdealer.
Notes:1. Thisgure()indicatesGRILLE’s.
2. Specicationssubjecttochangewithoutnotice.
Guaranteedoperatingrange
Indoor Outdoor *1
Cooling
Upper limit 35°C (95°F) D.B, 21.7°C (71°F) W.B 46°C (115°F) D.B
Lower limit 19.4°C (67°F) D.B, 13.9°C (57°F) W.B -10°C (14°F) D.B
Heating
Upper limit 26.7°C (80°F) D.B, 19.4°C (67°F) W.B 24°C (75°F) D.B, 18°C (65°F) W.B
Lower limit 21.1°C (70°F) D.B, 15.6°C (60°F) W.B -20°C (-4°F) D.B, -21°C (-5°F) W.B
*1 Depend on outdoor unit.
Units should be installed by licensed electric contractor accordingly to local code requirement.
9.Specications
Model SLZ-KF09NA SLZ-KF12NA SLZ-KF15NA SLZ-KF18NA
Power Supply (Voltage <V>, Frequency <Hz>) Single, 208/230, 60
Rated Input (Indoor only) <kW> 0.02 0.02 0.03 0.04
Rated Current (Indoor only) <A> 0.20 0.24 0.32 0.43
Dimension (Height) <inch> 9-21/32 (13/32)
Dimension (Width) <inch>
22-7/16 (24-19/32)
Dimension (Depth) <inch> 22-7/16 (24-19/32)
Fan airow rate (Low-Middle-High) <CFM> 230 - 265 - 300 230 - 280 - 335 245 - 315 - 405 300 - 420 - 475
Noise level (Low-Middle-High) <dB> 25 - 28 - 31 25 - 30 - 34 27 - 34 - 39 32 - 40 - 43
Net weight <lbs>
30.6 (5.3)
BH79A345H01_en.indd 17 2018/05/25 14:59:47