8.Installation,relocationandinspection
Warning:
Iftheairconditioneroperatesbutdoesnotcoolorheat(dependingonmodel)theroom,consultyourdealersincetheremaybearefrigerant
leak.Besuretoasktheservicerepresentativewhetherthereisrefrigerantleakageornotwhenrepairsarecarriedout.
Therefrigerantchargedintheairconditionerissafe.Refrigerantnormallydoesnotleak,however,ifrefrigerantgasleaksindoors,andcomes
intocontactwiththereofafanheater,spaceheater,stove,etc.,harmfulsubstanceswillbegenerated.
Electricalwork
• Provide an exclusive circuit for power supply of the air conditioner.
• Be sure to observe the breaker capacity.
Warning:
• Thecustomershouldnotinstallthisunit.Iftheunitisinstalledincorrectly,re,electricshock,injuryduetoafallingunit,waterleakage,etc.
mayresult.
• Donotconnectusingbranchedoutletoranextensioncord,anddonotattachmanyloadstooneelectricoutlet.
Areorelectricshockmayresultfrompoorcontact,poorinsulation,exceedingthepermissiblecurrent,etc.
Consultyourdealer.
Caution:
• Applygrounding
Donotconnectagroundingwiretoagaspipe,waterpipe,lightningrodorgroundwireofatelephone.
Ifagroundingisincorrect,itmaycauseanelectricshock.
• Installanearthleakagebreakerdependingontheplacewheretheairconditioneristobeinstalled(humidplace,etc.).
Iftheearthleakagebreakerisnotinstalled,itmaycauseanelectricshock.
Inspectionandmaintenance
• When the air conditioner is used for several seasons, the capacity may be lowered due to dirt inside the unit.
• Depending upon the conditions of use, an odor may be generated or dirt, dust, etc. may prevent proper drainage.
• It is recommended to apply inspection and maintenance (charged) by a specialist in addition to normal maintenance. Consult your dealer.
Alsoconsideroperationsound
• Do not put an object around the air outlet of the outdoor unit. It may cause lowering of capacity or increase operating sound.
• If abnormal sound is heard during operation, consult your dealer.
Relocation
• When the air conditioner is to be removed or reinstalled because of rebuilding, moving, etc., special techniques and work are required.
Warning:
Repairorrelocationshouldnotbedonebythecustomer.
Ifthisisdoneincorrectly,itmaycauseare,electricshock,injurybydroppingoftheunit,waterleakage,etc.Consultyourdealer.
Disposal
• To dispose of this product, consult your dealer.
Ifyouhaveanyquestion,consultyourdealer.
Notes:1. Thisgure()indicatesGRILLE’s.
2. Specicationssubjecttochangewithoutnotice.
Guaranteedoperatingrange
Indoor Outdoor *1
Cooling
Upper limit 35°C (95°F) D.B, 21.7°C (71°F) W.B 46°C (115°F) D.B
Lower limit 19.4°C (67°F) D.B, 13.9°C (57°F) W.B -10°C (14°F) D.B
Heating
Upper limit 26.7°C (80°F) D.B, 19.4°C (67°F) W.B 24°C (75°F) D.B, 18°C (65°F) W.B
Lower limit 21.1°C (70°F) D.B, 15.6°C (60°F) W.B -20°C (-4°F) D.B, -21°C (-5°F) W.B
*1 Depend on outdoor unit.
Units should be installed by licensed electric contractor accordingly to local code requirement.
9.Specications
Model SLZ-KF09NA SLZ-KF12NA SLZ-KF15NA SLZ-KF18NA
Power Supply (Voltage <V>, Frequency <Hz>) Single, 208/230, 60
Rated Input (Indoor only) <kW> 0.02 0.02 0.03 0.04
Rated Current (Indoor only) <A> 0.20 0.24 0.32 0.43
Dimension (Height) <inch> 9-21/32 (13/32)
Dimension (Width) <inch>
22-7/16 (24-19/32)
Dimension (Depth) <inch> 22-7/16 (24-19/32)
Fan airow rate (Low-Middle-High) <CFM> 230 - 265 - 300 230 - 280 - 335 245 - 315 - 405 300 - 420 - 475
Noise level (Low-Middle-High) <dB> 25 - 28 - 31 25 - 30 - 34 27 - 34 - 39 32 - 40 - 43
Net weight <lbs>
30.6 (5.3)