Indoor Installation Manual
Table Of Contents
- SVZ-KP12,18, 24, 30, 36NA
- Table of Contents
- SVZ-KP12,18, 24, 30, 36NA
- 1. Dimensions
- 2. Inspect shipment
- 3. Safety precautions
- 4. Indoor unit accessories
- 5. Selecting an installation site
- 6. Combining indoor units with outdoor units
- 7. Installing the unit
- 8. Side Return
- 9. Duct connection
- 10. Mount positions
- 11. Air filter
- 12. Refrigerant piping work
- 13. Drain connections
- 14. Electrical wiring
- 15. Test run
- SVZ-KP12,18, 24, 30, 36NA
- 1. Dimensions
- 2. Inspection du matériel livré
- 3. Mesures de sécurité
- 4. Accessoires de l’appareil intérieur
- 5. Sélection de l’emplacement d’installation
- 6. Combinaison des appareils intérieurs et extérieurs
- 7. Installation de l’appareil
- 8. Retour latéral
- 9. Raccordement des conduits
- 10. Positions de montage
- 11. Filtre à air
- 12. Travaux de tuyauterie de frigorigène
- 13. Raccordements de vidange
- 14. Câblage électrique
- 15. Essai de fonctionnement
- 15.1. Avant l’essai de fonctionnement
- 15.2. Essai de fonctionnement
- 15.3. Autotest
- 15.4. FONCTION D’AUTOREDÉMARRAGE
3.3. Before getting started
CAUTION
• Do not install the unit where combustible gas may leak.
– If the gas leaks and accumulates around the unit, an explosion may result.
• Do not use the air conditioner in special environments.
– Oil, steam, sulfuric smoke, etc. can significantly reduce the performance of the air
conditioner or damage its parts.
• When installing the unit in a hospital, communication station, or similar place, provide
sufficient protection against noise.
– The INVERTER equipment, private power generator, high-frequency medical equip-
ment, or radio communication equipment may cause the air conditioner to operate er-
roneously, or fail to operate. On the other hand, the air conditioner may affect such
equipment by creating noise that disturbs medical treatment of image broadcasting.
• Do not install the unit on a structure that may cause leakage.
– When the room humidity exceeds 80% or when the drain pipe is clogged, condensa-
tion may drip from the indoor unit. Perform collective drainage work together with the
outdoor unit, as required.
• When the ambient dew point temperature exceeds 75°F (24°C), dew condensation may
occur on the unit surface. Perform appropriate treatment to avoid dew condensation.