Installation Sheet

Table Of Contents
H120704 ASIME
PENDANT
www.hudsonvalleylighting.com/mitzi | #mymitzi
ASSEMBLY AND MOUNTING INSTRUCTIONS
GENERAL
WARNING-DISCONNECT POWER BEFORE RELAMPING OR
WIRING THE FIXTURE. TURN OFF THE ENTIRE ELECTRICAL
CIRCUIT TO WHICH THE LIGHTING FIXTURE IS ATTACHED
INSTALLATION AND MAINTENANCE OF THIS FIXTURE
SHOULD BE COMPLETED BY A LICENSED ELECTRICAN
FAILURE TO INSTALL FIXTURE CORRECTLY COULD RESULT
IN SERIOUS INJURY OR DEATH
READ ALL INSTRUCTIONS BEFORE STARTING INSTALLATION.
IF AN EXISTING FIXTURE IS BEING REPLACED, REMOVE IT AND
NOTE TO WHICH WIRE IN THE OUTLET BOX THE ORIGINAL
FIXTURE WAS ATTACHED.
BEFORE DISCARDING THE CARTON DOUBLE CHECK THE
PACKAGING TO MAKE SURE ALL PARTS HAVE BEEN FOUND.
THIS FIXTURE WAS DESIGNED TO BE MOUNTED TO AN
OCTAGON OUTLET BOX. THE BOX MUST BE SECURELY
MOUNTED TO THE STRUCTURE OF THE BUILDING.
INSTALLATION
STEP 1. Feed the wires through pipe stem, swivel, and mounting
plate. Twist stem tightly onto the body. Keep adding
additional stems to you desired height.
STEP 2. Slide in the canopy onto the stem, and thread the swivel
onto the stem.
STEP 3. Attach the mounting plate to the outlet box using the
mounting screws.
STEP 4. Trim excess wire to min 6” beyond the stem, strip each
wire to 5/8”.
STEP 5. Fasten bare ground wire to ground wire from the wall
outlet box (usually green or copper color) or connect
ground wire to green screw on the mounting plate.
STEP 6. Connect the neutral (white) fixture wire coming from the
fixture base to neutral (usually white) outlet wire. Fasten
ST
EP 7.
STEP 8.
STEP 9.
STEP 10.
both wires together with
a plastic wire nut and tightly
wrap the wire nut with electrical tape.
Repeat the previous step with the hot (black wires). Make
sure there are no exposed wires or strands that could
cause a dangerous short circuit.
FAILURE TO CONNECT THE APPROPRIATE WIRES
CORRECTLY COULD RESULT IN SERIOUS INJURY OR
DEATH!
Place the canopy with the fixture over the outlet box and
fasten it by the End ball nuts.
Install the lamp(s). The fixture is rated for 60 watt LED
type G lamp.
DO NOT EXCEED RECOMMENDED WATTATE!
Restore power to the circuit at breaker or fusebox.
DIMMING
The fixture can be controlled by a wall dimming device. Only use
triac/electronic dimmer. Make sure carton is marked for use with LED
compact fluorescent-incandescent light source only. These can be
provided by your local electrical distributor, home center, or
hardware store.
CLEANING
Please clean with a soft, dry cloth ONLY! Do not use cleaning products.

Summary of content (4 pages)