Installation Guide

Document Version: 11 26 | P a g e
© 2016 MiX Telematics International (Pty) Ltd.
Setting 1 (FACTORY
DEFAULT)
All Jumpers inserted
120 Ω Termination
under software control
RD/WR or "Listen Only"
mode is under software
control
When all SW1 jumpers are inserted, both CAN1 and CAN2 interfaces
are set for:
- 120 Ω termination is under software control (i.e. the software can
switch the 120 Ω resistor in or out of the circuit).
- RD/WR or "Listen Only" mode is under software control (i.e. the
software can transmit messages on the CAN bus).
Setting 2
All jumpers removed
NOT Terminated (120
Ω)
"Listen Only" mode
When all SW1 jumpers are removed, both CAN1 and CAN2 interfaces
are set for:
- 120 Ω termination is disabled (i.e. the 120 Ω termination resistor is
removed from the circuit and cannot be switched in by software).
- "Listen Only" mode (i.e. the software cannot transmit any messages).