Setting 3
Jumpers 3-4 and 7-8 inserted
120 Ω Termination is
under software control
"Listen Only" mode
When SW1 jumpers 3-4 and 7-8 are inserted, both CAN1 and CAN2
interfaces are set for:
- 120 Ω termination is under software control (i.e. the software can
switch the 120 Ω resistor in or out of the circuit).
- "Listen Only" mode (i.e. the software cannot transmit any messages).
Setting 4
Jumpers 1-2 and 5-6 inserted
NOT Terminated (120
Ω)
RD/WR or "Listen Only"
mode is under software
control
When SW1 jumpers 1-2 and 5-6 are inserted, both CAN1 and CAN2
interfaces are set for:
- RD/WR or "Listen Only" mode is under software control (i.e. the
software can transmit messages on the CAN bus).
- 120 Ω termination is disabled (the 120 Ω termination resistor is
removed from the circuit and cannot be switched in by software).