Product specifications

20
PX-3
Revision 01/04, Effective Date January 23, 2004
21
PX-3
Revision 01/04, Effective Date January 23, 2004
MAINTENANCE AND TROUBLESHOOTING
MOTOR BRUSH CHANGE-OUT
(B)
Remove the Motor Brush.
Clean the Brush Housing
(A)
Locate and remove one Motor
Cap Brush
(E)
Change the second
Motor Brush by repeating
steps (A) to (D)
(D)
Install the Motor Brush Cap
Disconnect the tool before servicing and when changing accessories, such as blades, bits, cutters, and
the like.
WARNING
!
1. Unplug the PX-3 from its power source and set it up for operation (See Setup, Adjustment and Operation)
NOTE:
When installing Motor Brushes, care must be teken to ensure the Spring End is straight before
installing the Motor Brush Cap.
(C)
Align and install the new
Motor Brush
One on either
side of motor