Product specifications

22
PX-3
Revision 01/04, Effective Date January 23, 2004
23
PX-3
Revision 01/04, Effective Date January 23, 2004
MAINTENANCE AND TROUBLESHOOTING
TROUBLESHOOTING
MOTOR STOPS TURNING
(B)
Check for proper rotation
(A)
Check for Smoothness or
“Glazing” (Dress blade if
needed)
(C)
Ensure the Blade Core is not
bent and Arbor is not out of
round
(D)
Verify the blade is correct for
the material being used.
(use only the PX-3 Diamond
Blades)
(E)
If the Blade is still not cutting
properly, contact MK at
(800) 262-1575
BLADE WILL NOT CUT PROPERLY
Verify the Lockable Switch is unlocked and the saw is disconnected from the power source
before performing any troubleshooting procedure.
WARNING
!
If the PX-3 Motor should stop turning, perform the following troubleshooting steps:
1. Verify all power cords and plugs are fully connected.
2. Verify the circuit breaker is 20 AMP or greater.
3. Verify the circuit breaker is not tripped. Reset if necessary.
4. Verify the source voltage is 115 volts.
5. If the Motor is still not turning after performing these troubleshooting steps, return your PX-3
to MK Diamond for repair.
If the PX-3 Blade does not cut properly, perform the following troubleshooting steps: