Manual

27
TROUBLESHOOTING:
Verify the Lockable Switch is unlocked and the saw is disconnected from the power source before
performing any troubleshooting procedure.
1. Motor Stops Turning:
2. Blade Will Not Cut Properly:
(A)
Verify all Plugs Fully Connected
If Connected, go to Step B
(B)
Check Ground Fault Circuit
Interrupter (GFCI) Tripped
(C)
Verify Circuit Breaker is
20 Amp or Greater
(E)
Verify Source Voltage
is 115 Volts
(D)
Verify Circuit Breaker
Not Tripped
(B)
Check for Proper Rotation
(A)
Check for Smoothness
or “Glazing”
(D)
Verify Blade Correct for
Material Being Used
(C)
Ensure Blade
Core Not Bent
If Rotation
Correct, go
to Step C
If not “Glazed,
go to Step B
Verif
y
Connected
If GFCI Tripped,
Reset and Restart
BX-3 once
If GFCI not Tripped,
go to Step C
If 20 Amp
Or Greater,
go to Step D
If Less than
20 Amps,
Switch to 20
Amp Breaker
If not
Tripped,
go to Step E
If Breaker Tripped,
Reset once -
Attempt Restart
If Circuit is
not115 Volts,
Change Circuit
If Circuit is 115
Volts, go to
Step F
If Rotation
Not Correct,
Reposition Blade
If “Glazed,” Dress
(See Blade Dressing)
If Core Not
Bent, go to
Step D
If Core Bent,
Chan
g
e Blade
If Blade
Correct, go
to Step E
Contact Place of Purchase or
MK Diamond (800 421-5830)
To Verify Blade
BX-3 TROUBLESHOOTING