Manual

BX-4 21
1 2 3 4 5 6
5 4 3 2 1
14
2
6
SETUP, ADJUSTMENT & OPERATION
5. ANGLE CUTS:
Angle Cuts may be performed using the Step Cut, Chop
Cut or the Locked Cutting Head cutting methods. The
following is utilizing the Locked Cutting Head method.
Loosen the knob (1) and remove the Adjustable
Cutting Guide (2).
Reposition the Adjustable Cutting Guide (2) by
aligning it at 45 degrees to slots on the Ruler/Stop (3).
Position masonry work (4) against the Adjustable Cutting
Guide (2) and Ruler/Stop (3).
Set Depth Control (5) & lock cutting head with knob (6).
(See Page 20)
Hold the masonry work in position. Lock the trigger
switch.
1
2
2
3
4
5