4. DIAMOND BLADE CHANGE-OUT:
Remove Retaining Screw (1) and Outer Flange (2):
Hold Shaft Wrench (3) stationary. Rotate Retaining
Screw counter-clockwise to loosen screw.
Remove Blade from Motor Shaft.
Seat Blade on the Inner Flange (4) under Blade
Guard and onto Motor Shaft. Note the
indicated rotation direction.
Install Outer Flange (2) and Retaining Screw (1):
Hold Shaft Wrench (3) stationary. Rotate and tighten
Retaining Screw (1) clockwise.
NOTE: When installing the Retaining Screw, do not
“cross-thread” and DO NOT over tighten the screw.
Disconnect the tool before servicing and when changing
accessories, such as blades, bits, cutters, and the like.
WARNING