Manual

38
(A)
Verify the cooling ow
Adjusting Clamp is open. If ow
exists, go to Step B.
(B)
Remove the Cooling Transfer
Tube from the Blade Guard
inlet. Go to Step C.
(C)
Place Pump into a bucket of
water and check ow. If ow
exists, go to Step D.
(D)
Remove the Cooling Transfer
Tube and check for ow. If ow
exists, refer to water pump
manual.
(E)
Remove the Blade Guard
Intake Fitting. Go to Step F.
(F)
Remove the Cooling Channel
cover screws. Go to step G.
(G)
Rod the Cooling Channels
and then recheck ow.
“Rodding” cooling channels is performed by inserting a small wire rod through the
cooling inlet on top of the Blade Guard and directing the rod out through each of the
cooling ow tubes located on the underside of the Blade Guard. The cooling chan-
nels should be “rodded” until all ports are free of foreign debris.
MK-101-24 TROUBLESHOOTING
Cooling Flow
NOTE: