36
(A)
Verify the cooling ow
Adjusting Clamp is open. If ow
exists, go to Step B.
(B)
Remove the Cooling Transfer
Tube from the Blade Guard
inlet. Go to Step C.
(C)
Place Pump into a bucket of
water and check ow. If ow
exists, go to Step D.
(D)
Remove the Cooling Transfer
Tube and check for ow. If ow
exists, refer to water pump
manual.
(E)
Remove the Blade Guard
Intake Fitting. Go to Step F.
(F)
Remove the Cooling Channel
cover screws. Go to step G.
(G)
Rod the Cooling Channels
and then recheck ow.
NOTE: “Rodding” cooling channels is performed by inserting a
small wire rod through the cooling inlet on top of the Blade Guard
and directing the rod out through each of the cooling ow tubes
located on the underside o the Blade Guard. The cooling chan-
nels should be “rodded” until all ports are free of foreign debris.
MK-101 Pro24 TROUBLESHOOTING
COOLING FLOW