Installation Guide
Page 1 of 4 
INSTALLATION SHEET 
Exterior Entry Systems 
Note: to install double door units see step 9; to install a door with sidelite(s) see step 8. 
Step 1: Prepare Rough Opening 
a) For rough opening dimensions, measure prehung unit from outside jamb to outside 
jamb. Add 1/2" to width and 3/4" to height to determine 
rough opening. if opening is oversize, fillers/shims may be required. (Rough opening sizes 
are also listed in full line catalog.) 
Step 2: Place Unit into Opening 
a) set unit into rough opening to verify fit, then remove. 
b) Thoroughly caulk floor/base area where the unit will be located with a high-grade 
silicone or non-hardening caulk. See Figure A. 
c) position unit into opening and center. 
Step 3: Shim and Secure Hinge Jamb 
a) plumb the hinge jamb and nail the brickmold at the hinge jamb with 16 d galvanized 
finish nails. 
b) Remove shipping bracket that holds door closed. Check to see that door swings freely. 
c) From the interior side, wedge shims between frame and studding at the three hinge 
locations and check for plumb (Figure B). 
d) Nail with 16 d finish nails through the hinge jamb, shims and studding. 
e) install two (2) security screws (#9 x 2-1/4" flat head wood screw) in the top hinge 
(Figure C). 