SDS

Name
CAS# Concentration* GHS Hazard Codes
1-DECENE, HOMOPOLYMER HYDROGENATED
68037-01-4 30 - < 40% H304
SEVERELY HYDROTREATED HEAVY PARAFFINIC
DISTILLATE
64742-54-7 30 - < 40% H304
SOLVENT DEWAXED HEAVY PARAFFINIC DISTILLATE
64742-65-0 1 - < 5% H304
* All concentrations are percent by weight unless material is a gas. Gas concentrations are in percent by volume.
As per paragraph (i) of 29 CFR 1910.1200, formulation is considered a trade secret and specific chemical identity and
exact percentage (concentration) of composition may have been withheld. Specific chemical identity and exact
percentage composition will be provided to health professionals, employees, or designated representatives in
accordance with applicable provisions of paragraph (i).
SECTION 4
FIRST AID MEASURES
INHALATION
Remove from further exposure. For those providing assistance, avoid exposure to yourself or others. Use
adequate respiratory protection. If respiratory irritation, dizziness, nausea, or unconsciousness occurs, seek
immediate medical assistance. If breathing has stopped, assist ventilation with a mechanical device or use
mouth-to-mouth resuscitation.
SKIN CONTACT
Wash contact areas with soap and water. If product is injected into or under the skin, or into any part of the
body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by
a physician as a surgical emergency. Even though initial symptoms from high pressure injection may be minimal
or absent, early surgical treatment within the first few hours may significantly reduce the ultimate extent of
injury.
EYE CONTACT
Flush thoroughly with water. If irritation occurs, get medical assistance.
INGESTION
First aid is normally not required. Seek medical attention if discomfort occurs.
SECTION 5
FIRE FIGHTING MEASURES
EXTINGUISHING MEDIA
Appropriate Extinguishing Media: Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish
flames.
Inappropriate Extinguishing Media: Straight Streams of Water
FIRE FIGHTING
Fire Fighting Instructions: Evacuate area. Prevent runoff from fire control or dilution from entering streams,
sewers, or drinking water supply. Firefighters should use standard protective equipment and in enclosed
spaces, self-contained breathing apparatus (SCBA). Use water spray to cool fire exposed surfaces and to
protect personnel.
Hazardous Combustion Products: Oxides of carbon, Incomplete combustion products, Aldehydes, Sulfur
oxides, Smoke, Fume
FLAMMABILITY PROPERTIES
Flash Point [Method]: >200°C (392°F) [ASTM D-92]