LED STATUS INDICATORS
Visual Reference System Status Condition Solution
LED is ashing blue.
1. Connect Provisioning Mode
2. Overcurrent when disarmed
1. In Connect Provisioning Mode; LEDs return to previous
Color when Provisioning is complete or times-out after
~1.5 minutes.
2. System has gone into overcurrent protection and user has
disarmed the system. Unplug any product which may be
drawing too much power. The system will self-heal.
LED is ashing yellow.
Ready to be Armed, provisioned
for Connect, but not communi-
cating to Connect Mesh Network
Ensure Connect Mesh is operating properly.
LED is solid yellow.
1. Armed, provisioned for Con-
nect, but not communicating
to Connect Mesh Network
2. Delete Whitelist Mode (If using
Authorization Card)
1. Ensure Connect Mesh is operating properly.
2. System is deleting whitelist. Wait until complete.
WARNINGS
1. For indoor use only, shall not be exposed to dripping or splashing.
2. Do not expose to excessive heat sources, sunshine, fire or the like.
3. The socket-outlet shall be installed near the equipment and shall be easily accessible.
4. No user replaceable parts inside, refer servicing to manufacturer specified agency or qualified service
personnel.
5. Only use accessories/battery specified by the manufacturer.
Disposal:
All electrical and electronic products including batteries should be disposed of separately
from the municipal waste stream via designated collection facilities appointed by the
government or the local authorities.