3.6 Starting the Camera Using the Factory IP Address
In certain situations, it may become necessary to start the camera with its factory IP
address. This could be the case, for example, if the IP address has been lost or the
camera does not react to the last known IP address.
Proceed as follows to start the camera using its factory IP address:
If the camera is powered on, disconnect the power supply of the camera by
unplugging the corresponding cable.
Reconnect power to the camera and observe the LEDs.
Wait until both LEDs are lighting up simultaneously for the first time.
Press the "L" key on the camera within four seconds.
After about two more seconds, the camera plays a single sound ("Boing"), if
an external speaker has been connected.
The camera is now accessible again using its factory IP address (see label on
the camera housing).
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • sales@mobotix.com
95/100
D22M Camera Manual Part 1
Passwords and camera
settings will not be chan-
ged!
The D22 also allows con-
necting an external spe-
aker and microphone.
The D22 does not have a
built-in speaker or
microphone.
Make sure you store the
factory network configu-
ration to the permanent
flash memory
Users and passwords will
not be changed!
Note
If you use the camera's "L" key to load the factory network configurati-
on, this configuration is not automatically saved to flash memory.
Upon restarting the camera the next time without using the camera's
"L" key, the
last stored network configuration
will be used. To perma-
nently store the new network configuration in the camera's flash me-
mory, open Admin Menu> Store ...
Caution
As opposed to resetting the camera using
Admin Menu> Reset
configuration to factory defaults
, the user information will
not
be re-
set if the camera is booted using the factory IP address.
Press "L" key