3.6.3 Permanently Deactivating the Microphone
Deactivating a camera’s microphone may be necessary in order to protect the privacy of
persons at a workplace or for other reasons. You can permanently and irreversibly deac
-
tivate the microphone in the Admin Menu> Loudspeaker and Microphone dialog box.
3.6.4 Starting the Camera with the Factory IP Address
If the camera’s IP address is not known, you can start the camera with its factory IP
address.
Section 3.2.6, «Starting The Camera With The Factory IP Address»
describes this
procedure in more detail.
3.6.5 Resetting the Camera to Factory Settings
All settings of the MOBOTIX camera can be permanently reset to the factory default settings.
This makes sense if you have, for example, obtained a camera without any information
or you would like to reset all settings after testing the camera. In order to perform this
procedure, you need to have administrative access to the camera (admins group). Open
Admin Menu > Reset to reset the camera to factory defaults.
Note
All defined users are deleted and the admin password is reset to the factory default
when you reset the camera using Admin Menu > Reset. If you want to maintain the
existing users, use the method described in
Section 3.2.6, «Starting The Camera With
The Factory IP Address»
.
3.6.6 Activating Event Control and Motion Detection
In its default configuration, the camera’s event control and video motion detection features
are not enabled. In order to activate event-controlled recording, open Setup Menu>
General Event Settings and activate the Arming switch. Another method is to click on the
Arm & Record softbutton in the browser’s user interface. The camera displays the motion
detection window in the live image (dotted frame in the center) and the camera auto
-
matically stores images as soon as the motion detection window detects movements.
3.6.7 Deactivating Text and Logo Options
As camera arming is deactivated in the camera’s default configuration (see preceding
section), the MOBOTIX camera only displays the text www.mobotix.com, the time stamp
and the MOBOTIX logo at the top of the image. Once the camera arming has been acti-
vated, the text at the bottom of the live image (event, action, messaging and recording
symbols) will also appear.
You can deactivate the status bar at the bottom of the live image and the text bar in the
top left-hand corner by setting Text Display in the Setup Menu> Text & Display Settings
dialog box to O. Setting Text Display to Date and Time will only display the time stamp
in the live image. To hide the logo in the live image, open Admin Menu> Logo Profiles
and set Logo Display to Deactivated.
The microphone can be
irreversibly deactivated!
You can reset spe-
cic parts of the
conguration
If the dotted rect-
angle in the live
image is visible, the
camera is armed
Text and logos can be
also deactivated or
individually congured